33
d.
Enter the management tag (VLAN ID) and the priority (optional).
Is a VLAN tag required on Management packets? [ Y ]
The Management Tag is [7 ]
Management Priority is [0 ]
e.
Ensure the
Are VLAN Tags required on the EXT Port?
field is set to
N.
Are VLAN Tags required on the EXT Port? [ N ]
f.
Press
S
or
F3
to save the settings. This will set all traffic with VLAN ID 7 as
management.
g.
Type
reboot
.
Now the iMcV-Giga-FiberLinX-II is configured to pass all data between the OPTICS
(UPLINK) and DATA ports, except data tagged with VLAN ID 7. All data tagged with
VLAN ID 7 is considered management traffic and passes from the OPTICS (UPLINK)
port to the EXT MGMT port only. The iMcV-Giga-FiberLinX-II is configured to
receive untagged data from the twisted pair EXT MGMT port and add the VLAN ID 7
before sending it out of the OPTICS (or UPLINK) port. In this mode the EXT MGMT
port provides a secure link to the management port at the other end of the fiber line.
DATA:
Off Untagged Data and Tagged Data
(
without mana
g
ement-
V
LAN #7
)
EXT MGMT:
On Management
OPTICS:
Untagged Data, Tagged Data
including management with
V
LAN ID = 7
On
Port
SNMP
DIP Switch
Settings
1-EXT MGMT=ON
2-DATA=OFF
3-OPTICS=ON