17
Burner and nozzle characteristicsTable 1 Liquid Gas Natural Gas
Burner Diameter
(mm) Thermal Power
kW (p.c.s.*) By-Pass
1/100 Nozzle
1/100 Flow*
g/h Nozzle
1/100 Flow*
l/h
Nominal Reduced (mm ) (mm ) *** ** (mm)
Fast
(Large)(R) 100 3,00 0,7 41 86 218 214 116 286
Ultrarapid
(Large)(UR) 100 3,30 0,7 41 91 240 236 123 314
Semi Fast
(Medium)(S) 75 1,90 0,4 30 70 138 136 106 181
Auxiliary
(Small)(A) 55 1,00 0,4 30 50 73 71 79 95
Oven - 2,60 1,0 52 78 189 186 119 248
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m3
Technical CharacteristicsInner dimensions of the oven:
Width: 43.5 cm
Depth: 43.5 cm
Height: 31 cm
Inner Volume of the Oven:
58 lt
Innder dimensions of the plate plate warmer:
Width: 46 cm
Depth: 42 cm
Height: 8.5 cm
Voltage and Frequency of Power Supply:
see data plate
Burners:
adaptable for use with all the types of gas indicated on
the data plate
This appliance conforms with the following European
Economic Community directives:
- 73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
- 89/336/EEC of 03/05/89 (Electromagnetic Compatibility)
and subsequent modifications;
- 90/396/EEC of 29/06/90 (Gas) and subsequent
modifications (only for models which use gas);
- 93/68/EEC of 22/07/93 and subsequent modifications.
- 2002/96/EEC