Installation

Installation

! Before operating your new appliance please read

GB this instruction booklet carefully. It contains important information concerning the safe installation and operation of the appliance.

!Please keep these operating instructions for future reference. Make sure that the instructions are kept with the appliance if it is sold, given away or moved.

!The appliance must be installed by a qualified professional according to the instructions provided.

!Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply.

Positioning and levelling

!It is possible to install the appliance alongside cupboards whose height does not exceed that of the hob surface.

!Make sure that the wall in contact with the back of the appliance is made from a non-flammable, heat- resistant material (T 90°C).

To install the appliance correctly:

Place it in the kitchen, the dining room or the bed- sit (not in the bathroom).

If the top of the hob is higher than the cupboards, the appliance must be installed at least 600 mm away from them.

Levelling

If it is necessary to level the appliance, screw the adjustable feet into the places provided on each corner of the base of the cooker (see figure).

The legs* fit into the slots on the underside of the base of the cooker.

Electrical connection

WARNING – THIS APPLIANCE MUST BE EARTHED.

The appliance is designed to work with alternating current at the supply voltage and frequency indicated on the rating plate (situated on the rear part of the appliance and on the last page of the instruction booklet) or at the end of the instruction booklet. Make sure that the local supply voltage corresponds to the voltage indicated on the rating plate.

To connect directly to the mains supply, a double- pole switch with a contact separation of at least 3

mm suitable for the load and complying with current

Min. 420mm.

HOOD

Min. 900mm.

Min. 420mm.

min. 650 mm. with hood min. 700 mm. without hood

If the cooker is installed underneath a wall cabinet, there must be a minimum distance of 420 mm between this cabinet and the top of the hob.

This distance should be increased to 700 mm if the wall cabinets are flammable (see figure).

standards and regulations, must be fitted between

the appliance and the mains supply outlet. The

yellow-green earth wire must not be interrupted by

the switch. The supply cable must be in such a

position that no part of it can reach a temperature of

50 °C above room temperature. Do not use adapters

or shunts as they could cause heating or burning.

Before connecting to the power supply, make sure

that:

• the limiter valve and the domestic system can

withstand the load from the appliance (see rating

plate);

Do not position blinds behind the cooker or less than 200 mm away from its sides.

Any hoods must be installed according to the instructions listed in the relevant operating manual.

• the supply system is efficiently earthed according

to standards and laws in force;

• the socket or double-pole switch are easily

accessible when the appliance is installed.

FAILURE TO OBSERVE THE ACCIDENT- PREVENTION REGULATIONS RELIEVES THE MANUFACTURER OF ALL LIABILITY.

Important: the wires in the mains lead are coloured in accordance with the following code: