TSS-1100

TSS-1100 150W Powered Sub/ Plate Amp

 

 

 

 

 

 

 

 

 

 

 

 

LINE VOLTAGE

Yes/No

Hi/Lo Line

 

Nom.

Unit

 

Notes

US 120vac/60Hz

Yes

108-132

 

120

Vrms

Normal Operation

 

EU 230vac/50-60Hz

Yes

207-264

 

230

Vrms

Normal operation, MOMS required

 

 

 

 

 

 

 

 

 

 

 

 

QA Test

 

 

 

Parameter

Specification

Unit

 

Limits

Conditions

 

Notes

 

 

 

 

 

 

 

 

Amp Section

 

 

 

 

 

 

 

Type (Class AB, D, other)

D

 

 

 

 

 

 

Load Impedance (speaker)

5.6

Ohms

 

n/a

Nominal

 

 

Rated Output Power (120VAC

150

Watts

 

110

 

Domestic version only 120 VAC-60 Hz

Rated Output Power (230VAC

150

Watts

 

110

 

EU Version only

230 VAC-50 Hz

 

 

 

 

 

 

Average RMS power, 3/20 Cycles 50 Hz, Driven

AVG RMS Dynamic Power

250

Watts

 

225

 

6dB above its input sensitivity sensitivity

THD @ Rated Power

0.5

%

 

1

22K filter

145 Watts

 

THD @ 1 Watt

0.1

%

 

0.5

22K filter

 

 

DC Offset

10

mV-DC

 

30

Amplifier output

 

 

 

 

 

 

 

 

Measured at the amplifier board. 120 Watts @

Damping factor

>50

DF

 

20

Measured at amplifier board

50 Hz, THD must be less tan 0.1%

 

 

 

 

 

 

 

 

Input Sensitivity

 

 

 

 

 

 

 

Input Frequency

35

Hz

 

35

Nominal Freq.

 

 

L&R

188

mVrms

 

±2dB

To 110 Watts, Ap Zo=600 Ohms

Single input driven

 

L or R input

188

mVrms

 

±2dB

To 110 Watts , Ap Zo=600 Ohms

Single input driven, LFE switch ON

 

 

 

 

 

 

Single input driven, LP switch to Normal, This

Speaker/Hi Level Input

1.68

Vrms

 

±2dB

To 120 Watts

applies to 230VAC model only

 

 

 

 

 

 

 

 

Signal to Noise

 

 

 

 

 

 

 

SNR-A-Weighted

90

dBA

 

85

relative to rated power

A-Weighting filter

 

SNR-unweighted

85

dBr

 

80

relative to rated power

22K filter

 

SNR rel. 1W-unweighted

65

dBr

 

60

relative to 1W Output

22K filter

 

 

 

 

 

 

Volume @max, w/ A/P Swept

 

 

 

 

 

 

1.5

Bandpass Measurement (Line

Line level inputs must be terminated using

Residual Noise Floor

1

mVrms(max)

 

freq.+ harmonics) (BW=20 Khz)

1KOHM

 

 

 

 

 

 

 

 

 

Input Impedance

 

 

 

 

 

 

 

Line Input (L, R,LFE)

10K

ohms

 

n/a

Nominal

 

 

Speaker/Hi Level Input

> 4.7K

ohms

 

n/a

Nominal

 

 

 

 

 

 

 

 

 

 

Filters

 

 

 

 

 

 

 

LP filter 4th order fixed

50-150

Hz

 

± 10

2nd Order variable and 2nd order fix

2nd order variable + 2nd order fix-24 db/Octave

HP Filter 2nd order

Fixed

 

 

 

 

 

 

LFE Low pass 2nd order

200>LP<1K

Hz

 

 

LFE input driven only

 

 

Notch filter (Friend circuit)

 

 

 

 

F=61 Hz, Q=3.607, Av=-8.62dB

 

 

HP speaker out connector

1st order fix

 

 

 

 

 

 

Left & Right

200

Hz

 

± 10

Speaker input - Spkr out 4 Ohms

(Applies to 230VAC model only)

Left & Right

100

Hz

 

± 10

Speaker input - Spkr out 8 Ohms

(Appies to 230VAC model only)

 

 

 

 

 

 

 

 

Limiter

 

 

 

 

 

 

 

THD at Max. Output Power

n/a

n/a

 

functional

Maximum Output Power

Maximum THD as a result of limiting.

 

 

 

 

 

 

 

 

Features

--

 

 

 

 

 

 

Volume pot Taper (lin/log)

LOG

--

 

functional

 

A Taper

 

Speaker input connectors

YES

 

 

functional

 

L&R Speaker input binding post connectors

 

 

 

 

 

 

L&R Speaker out with HP applies only to

HP Speaker out

YES

 

 

functional

 

230VAC models

 

Phase switch

0-180

deg

 

functional

 

 

 

LP Filter defeat switch

YES

 

 

functional

 

Disables LP filter, intended for LFE

 

 

 

 

 

 

 

 

Input Configuration

 

 

 

 

 

 

 

Line In (L,R) & LFE

YES

--

 

functional

 

Dual RCA jack

 

 

 

 

 

 

 

Binding post connector L&R (Applies to

Spkr/Hi Level In

YES

--

 

functional

 

230VAC model only)

 

 

 

 

 

 

 

 

 

Signal Sensing (ATO)

 

 

 

 

 

 

 

Auto-Turn-On (yes/no)

YES

 

 

functional

 

 

 

ATO Input test frequency

50

Hz

 

functional

 

 

 

ATO Level LFE Input

2

mV

 

functional

 

Maximum acceptable level.

 

 

 

 

 

 

Maximum acceptable level. (Applies to 230VAC

ATO Level Speaker in

40

mV

 

functional

 

model only)

 

 

 

 

 

 

Amp connected and AC on, then

 

 

ATO Turn-on time

5

ms

 

functional

input signal applied

 

 

 

 

 

 

 

T before muting, after line or

Auto turn of time (T)

must be 5 > T < 18

Auto Mute/ Turn-OFF Time

15

minutes

 

18

speaker level signal is removed

Minutes

 

 

 

 

 

 

 

 

 

Power on Delay time

3

sec.

 

4

AC Power Applied

 

 

2

Page 3
Image 3
Infinity 6 - Piece Home Theater System service manual TSS-1100 150W Powered Sub/ Plate Amp