4. Change rotation speed

High speed

Low speed

Shift knob

Shift knob

Fig. 7

Fig. 8

Operate the shift knob to change the rotational speed. Move the shift knob in the direction of the arrow (see Figs. 7 and 8).

When the shift knob is set to “LOW”, the drill rotates at a low speed. When set to “HIGH”, the drill rotates at a high speed.

CAUTION:

When changing the rotational speed with the shift knob, confirm that the switch is off. Changing the speed while the motor is rotating will damage the gears.

When a large force is required for operation (operations indicated in the following chart) set the shift knob to “LOW”. If “HIGH” is set and the unit is used, it may cause the motor to burn out or malfunction prematurely.

 

Table 2

 

 

Model

DS12DVF / DS14DVF

 

 

Metal Drilling

When the diameter of the hole exceeds 1/4"(6.5mm).

 

 

Wood Drilling

When the diameter of the hole exceeds 15/32"(12mm).

 

 

Wood Screw Tightening

When the size of the wood screw exceeds 5/32"(3.8mm)

 

diameter 1-31/32"(50mm).

5. Confirm the cap position (see Fig. 9)

Triangle

 

The tightening torque of this unit can be adjusted

 

according to the cap position, at which the cap is

Cap mark

 

mark

set.

 

Weak

 

(1) When using this unit as a screwdriver, line up the

 

 

one of the numbers “1, 3, 5 ... 22” on the cap, or

 

 

the black dot, with the triangle mark on the outer

 

 

body.

 

 

(2) When using this unit as a drill, line up the cap drill

Strong

 

mark “ ” with the triangle mark on the outer

 

body.

 

 