InFocus 3534324301 Manual del usuario de IN3138HD, Función, Comando, Predeter, Paso, Parámetro

Models: 3534324301 IN3138HD

1 67
Download 67 pages 44.57 Kb
Page 65
Image 65
E20.8

Manual del usuario de IN3138HD

Función

Comando

RW

Mín.

Máx.

Predeter

Paso

Parámetro

 

 

 

 

 

 

minado

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valid only when Display

 

 

 

 

 

 

Source

 

Mode = User

16V

Color Temp

TMP

RW

0

2

1

0:Warm

Specific

 

 

 

 

 

 

 

1:Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2:Cold

17V

Contrast

CON

RW

0

100

50

1

Valid only when Display

Mode = User

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:VGA1

 

 

 

 

 

 

 

 

1:VGA2

18V

Current Source

SRC

RW

0

13

0

1

5:HDMI-1

7:DP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12:Video

 

 

 

 

 

 

 

 

13:S-Video

21V

Digital Zoom

DZM

RW

-10

10

0

1

-10~10

 

 

 

 

 

 

 

 

0:No error

 

 

 

 

 

 

 

 

1:Lamp not lit after 5 At-

 

 

 

 

 

 

 

 

tempts

 

 

 

 

 

 

 

 

3:Lamp went out unexpect-

27V

Error Condition

ERR

R

n/a

n/a

n/a

n/a

edly

4:Fan failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5: Overheating

 

 

 

 

 

 

 

 

7: Case open

 

 

 

 

 

 

 

 

8:DMD error

 

 

 

 

 

 

 

 

9:Color wheel

28V

Factory Reset

RST

W

n/a

1

1

1

1:reset

32V

Freeze Screen

FRZ

RW

0

1

0

1

0:Disable

 

 

 

 

 

 

 

 

Valid only when Display

 

 

 

 

 

 

 

 

Mode = User

 

 

 

 

 

 

 

 

0:1.8

34V

Gamma

GTB

RW

0

5

Source

1

1:2.0

Specific

2:2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3:2.4

 

 

 

 

 

 

 

 

4:B&W

 

 

 

 

 

 

 

 

5:Linear

40V

Horz. Position

HPS

RW

-5

5

0

1

RGB source only

(HPS?) to get range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displays the number of

45V

Lamp Hours in High

LMO

R

0

9999

 

 

hours that the current lamp

Power Mode

 

 

has run in High Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Normal) mode.

 

 

 

 

 

 

 

 

Displays the number of

46V

Lamp Hours in Low

LME

R

0

9999

 

 

hours that the current lamp

Power Mode

 

 

has run in Low Power (Eco)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode.

47V

Lamp Life

LIF

R

n/a

Note

 

 

280W lamp life 3000 on

 

 

E20.8

 

 

 

 

 

 

 

 

49V

Lamp Resets (Total

LMR

R

0

9999

0

1

 

number)

 

 

 

 

 

 

 

 

 

62V

Lamp Low Power

IPM

RW

0

1

0

1

0=ECO, 1=Normal

58

Page 65
Image 65
InFocus 3534324301 manual Manual del usuario de IN3138HD, Función, Comando, Predeter, Paso, Parámetro, minado, E20.8