43
For IN5504 and IN5502 (Single Lamp)1Turn the projector off and unplug the power cord.
2Wait 60 minutes to allow the projector to cool thoroughly.
3Remove the lamp door:
(a) release the top latches by sliding the release buttons toward the rear
of the projector
(b) slide the top front cover towards the direction of the lens,
(c) remove the 5 screws, then lift the lamp door off.
4Loosen the 2 captive screws that attach the lamp housing to the projec-
tor. Carefully remove the lamp housing. Dispose of the lamp in an envi-
ronmentally proper manner in accordance with local disposal laws.
5Install the new lamp housing and tighten the 2 screws.
6Replace the lamp door by securing the 5 screws.
7Replace the top front cover by sliding it back into place.
8Plug in the power cord and press the Power button to turn the projector
back on.
9To reset the lamp hour timer, navigate to the Status and Service menu and
select Reset Lamp Hours. See page 33 for details.
Turn off and
unplug projector
Wait 60
minutes
(3b)
(3c)
(4)
(3a)
(3a)
SP-LAMP-055