InFocus LP225 manual Communication Configuration, RS-232 Port Settings, Value, Command Format

Models: LP225 SP-CWRS232

1 3
Download 3 pages 38.14 Kb
Page 1
Image 1
LP225 RS-232 Command Values

LP225 RS-232 Command Values

Communication Configuration

To control one of the above noted projectors from an RS-232 control system, connect the serial cable or a null modem cable and the InFocus RS-232 Adapter (SP-CWRS232) and set the control system serial port settings to match the following communication configuration*:

 

RS-232 Port Settings

 

Setting

 

Value

Bits per second

 

19,200

Data bits

 

8

 

 

 

Parity

 

None

Stop bits

 

1

 

 

 

Flow control

 

None

 

 

 

Emulation

 

VT100

RS-232 Connection for LP225

The RS-232/serial connection for these projectors is located on the PC side of the CableWizard II connection hub. Use the serial cable (IFS part # 210-0107-xx) to connect the CableWizard II to the serial port of the computer source.

Note: CableWizard3 (p/n SP-CW3) does not support RS-232. You must Use CableWizard II (p/n SP-CW2) and the InFocus serial cable.

Command Format

All commands consist of 3 alpha characters followed by a request, all enclosed in parentheses. The request can be a read request (indicated by a "?") or a write request (indicated by 1 to 4 ASCII digits).

A read request example:

(AAA?) where

( starts the command

AAAdenotes the command ? denotes the read request ) ends the command

A read command returns the range and the current setting, for example:

Read Command Examples

 

Function

 

Command

 

Response

 

Brightness

 

(BRT?)

(0-22,

10)

 

Volume

 

(VOL?)

(0-80,

0)

 

Lamp Hours

 

(LMP?)

(0-9999, 421)

 

 

 

 

 

 

 