Image 1
i7910 GPRS

To charge the battery:

Make sure battery pack is properly seated in i7910.

Plug the power adapter into the wall outlet and into the power connector at the back of i7910 terminal.

Use the power adapter supplied with i7910. Many adapters can appear similar and will plug into i7910 but will not work properly causing erratic behavior, poor charging or damage to the unit.

The i7910 with a fully charged battery can perform up to 200 transactions (depending of the ticket size, transaction duration, time between transactions and backlight usage).

The battery status is updated on the i7910 display (the indicator depends of the application running on i7910):

1 bar represents 25 % of full capacity,

2 bars represent 50 % of full capacity,

3 bars represent 75 % of full capacity, 4 bars represent full capacity.

-Do not short-circuit batteries.

-Do not open or alter batteries’ outside structure.

-Do not expose battery to fire, do not heat it.

-Do not expose battery to liquid, do not freeze it.

Store batteries at 40% charge level in a cool and dry area. The recommended storage temperature is 15°C (59°F). Re-charge them to 40% every 3 to 4 months.

3.5.Connections:

Turn the terminal off before connecting peripherals.

Power

RS-2332

supply

port

connector

 

PERIPHERAL CONNECTION

Connect the serial cable to the RS-232port. Plug the other end of the serial cable to the device (PC, bar code or check reader etc.). For detailed instructions, ask the equipment supplier.

POWER CONNECTION

Plug the power adapter radial jack into power supply connector at the back of i7910. Plug the power adapter into the wall outlet.

The power supply:

INPUT

100-240 VAC, 50-60Hz

OUTPUT

18VDC, 1A

OPTIONAL LinkBox and ComBox MODULES These modules provide additional connections:

LinkBox provides a back-up dial connection (asynchronous and synchronous, V22bis or V34) and powered RS-232 port. ComBox provides two RS-232 ports, one of them powered (port marked RS232-2 provides power for the attached device).

Connect LinkBox or ComBox to the i7910 RS-232 port, the letters “TOP” on a connector must be facing up. The green light (LinkBox only) indicates modem is ready. The light becomes red while dial connection is used.

Connecting LinkBox to a telephone line: Plug the one end

of a telephone cable into the port marked Installation Guide, and plug the other end of a telephone cable into a wall telephone jack.

Attaching device to LinkBox or ComBox RS-232 port: Connect the serial cable to the RS-232port. Plug the other end of the serial cable to the device (PC, ECR, bar code or check reader etc.).

4.Normal Operation:

Depending of the application installed in the terminal, i7910 displays icons indicating:

battery charge level,

charging status and

received signal strength.

Depending of the application, the i7910 terminal powers down after a period of inactivity (in order to prolong battery life). Pressing the green <OK> key powers i7910 back on.

The i7910 with a fully charged battery can perform up to 200 transactions (depending of the ticket size, transaction duration, time between transactions and backlight usage).

5.Cleaning procedure:

The i7910 must be off for all cleaning operations.

Do not clean the i7910 with water but with a dry or only slightly damp cloth.

Do not use solvent, detergent or abrasive products.

If the terminal has battery charging problem, clean the

contacts on the battery and on the terminal with a damp cloth Do not scratch or scrape the surface of the contacts.

If the print quality deteriorates, clean the print head to remove accumulated paper dust. The print head must be cleaned with the terminal powered off, using ethanol applied on a lint-free cloth.

Be aware of the sharp paper cutter and hot printer parts. Ensure that the ethanol has completely evaporated before switching the terminal back on.

6.If you experience problems:

HELP DESK NUMBER: 1-888-900-8221

CUSTOMER SERVICE CENTERS:

In Canada:

In the USA:

6520 Gottardo Court

6195 Shiloh Road, Suite D

Mississauga, Ontario, L5T 2A2

Alpharetta, Georgia 30005

1-888-900-8221 (905-795-8221)

1-800-252-1140 (678-456-1200)

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

. Reorient or relocate the receiving antenna.

. Increase the separation between the equipment and receiver.

. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

. Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by Ingenico could void the user’s authority to operate the equipment.

Canadian Department of Communications (DOC) Warnings:

This digital apparatus does not exceed the Class B limits for radio noise emissions from the digital apparatus as set out in the radio interference regulations of the Canadian Department of Communications.

RF Exposure Warning:

This unit has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in FCC/OET Bulletin 65 Supplement C (2001) and IEEE Std. 1528-200X (Draft 6.5, January 2002).

This device and its antenna must not be co-located or operating with any other antenna or transmitter except Grant condition. Users are not permitted to modify this transmitter device. Any unauthorized change made to this device could void your authority to operate this device.

For body worn operation, to maintain compliance with FCC RF exposure guidelines, use only accessories that contain no metallic components and provide a separation distance of 15mm (0.6 inches) to the body. Use of other accessories may violate FCC RF exposure guidelines and should be avoided.

Ministry of Health (Canada), Safety Code 6. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg *.

*In the U.S. and Canada, the SAR limit for mobile terminals used by the public is 1.6 watts/kg (W/kg) averaged over one gram of tissue. The standard incorporates a substantial margin of safety to give additional protection for the public and to account for any variations in measurements.

Ingenico Inc.

6195 Shiloh Road, Suite D, Alpharetta, Georgia 30005

Tel: (678) 456 – 1200 Fax: (678) 456 – 1201

www.ingenico-us.com

Ingenico Canada Ltd.

79 Torbarrie Road, Toronto, Ontario, Canada, M3L 1G5 Tel: (416) 245 – 6700 Fax: (416) 245 – 6701

www.ingenico-ca.com

i7910 GPRS

Installation Guide

DIV450006A

Page 1
Image 1
Ingenico I7910 manual DIV450006A, i7910 GPRS, Installation Guide