EN-2 04584744_ed5
EN
Model
Sound Level dB(A)
(ISO15744)
Vibration
(ISO28927) m/s²
† Pressure (Lp) ‡ Power (Lw) Level *K
261, 261-EU 98.1 109.1 10.4 1.3
261-3, 261-3-EU 98.1 109.1 10.4 1.3
261-6, 261-6-EU 98.1 109.1 10.4 1.3
271, 271-EU 98.1 109.1 13.2 1.1
† KpA = 3dB measurement uncertanity
‡ KwA = 3dB measurement uncertanity
* K = Vibration measurement uncertanity
Installation and Lubrication
Size air supply line to ensure tool’s maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air lter and compressor tank daily. Install
a properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any
hose coupling without internal shut-o, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 47132600 and table on page 2. Maintenance frequency is shown in a
circular arrow and dened as h=hours, d=days, and m=months of actual use. Items identied as:
1. Air lter 7. Coupling
2. Regulator 8. Safety Air Fuse
3. Lubricator 9. Oil
4. Emergency shut-o valve 10. Grease - during assembly
5. Hose diameter 11. Grease - through tting
6. Thread size
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Oce or Distributor.