E2000 D PRINTED IN U.S.A.
&
(419) 636-4242
D
F
AX (419) 633-1674
INGERSOLL-RAND COMPANY
P.O.BOX 151 DONE ARO CENTER DBRYAN,OHIO 43506Ć0151
OPERATOR’S MANUAL650517
RELEASED: 4-10-97
REVISED:
9-15-00
(REV
. C)
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

650517 & 650518

ALSOINCLUDE MANUALS: PH10AĆXĆX HIGH PRESSURE DIAPHRAGM PUMP (PN 97999Ć801), 6661MXĆXĆC DIAPHRAGM PUMP
(PN97999Ć619), L262X1ĆXXX REGULATOR (PN 100400Ć7), P292X1ĆXXX PIGGYBACK FILTER / REGULATOR (PN 100400Ć8).
1”
DIAPHRAGM PUMP
, 3:1 RATIO, WITH WALL MOUNT

DELIVERY

SYSTEM

650518
SERVICE KITS
Use only genuine ARO replacement parts to assure compatible presĆ
sure rating and longest service life.
Fluid Section Repair Kit 637179.
Air Section Repair Kit 637178.
Refer to the 6661MXĆXĆC Operator's Manual for parts / repair and serĆ
vice information (model 650517).
Refer to the PH10AĆXĆX Operator's Manual for parts / repair and serĆ
vice information (model 650518).
PUMP
SYSTEM DA
TA
System Model 650517 (aluminum)..........
650518 (stainless steel)
Basic Pump Model 6661M0Ć2A4ĆC (aluminum).....
PH10AĆASSĆSST (stainless steel)
Pump Type 3:1 Ratio, Metallic Air Operated Double...........
Diaphragm with stainless steel seats
Material Aluminum..............
Air Inlet 3/8" Ć 18 N.P.T.F...............
Maximum Air Inlet Pressure 100 p.s.i.g. (6.9 bar)
Maximum Outlet Pressure 300 p.s.i.g. (20.4 bar)
Maximum Flow Rate 24 g.p.m. (90.7 l/m)....
Maximum Particle Size 1/8" (3.2 mm)..
Maximum Temp. Limits 35_to 150_F(2_to66_C)..
Noise Levelh84.5 db(A) @ 70 psi, 60cycles per minute...........
hThepumpsoundpressurelevels publishedherehavebeenupdatedtoan EquivalentContinuousSoundLevel
(LAeq)to meet the intent of ANSI S1.13Ć1971, CAGIĆPNEUROP S5.1 using four microphone locations.
GENERAL
DESCRIPTION
The 650517 & 650718 Wall Mount Pumping System includes fittings,
wall bracket, regulator, siphon tube, gauge and hardware.
The diaphragm pump uses stainless steel balls and seats, and teflon
diaphragms and is designed to be used with waterborne paints. The
gun and low pressure air and material hoses are not included.
OPERATING INSTRUCTIONS
WARNING
DONOT EXCEED MAXIMUM OPERATING PRESĆ
SURE OF 300P.S.I. (20.4 BAR) AT 100P.S.I. (6.9 BAR) AIR INĆ
LET PRESSURE.
WARNING READ THE PUMP MANUAL FOR ADDITIONAL
OPERATING AND SAFETY PRECAUTIONS AND OTHER IMĆ
PORTANT INFORMATION.
INITIAL
SETUP PROCEDURE
Install the connector to the air supply hose.
Attach (17) ground kit to ground lug.
Attach the ground wire to a suitable ground.
Keep containers covered to prevent contamination.
When using an agitator, install a T" at the air inlet or use a sepĆ
arate air supply source.
START-UP
1. Turn the knob on the air regulator counterclockwise to zero p.s.i.
2. Place (11) tube into the container of material.
3. Start the pump to cycle by turning the air regulator knob clockwise.
The pump willcycle several strokes until pressure is built up in the
system, at which time it will stop. Check for any loose fittings or
leakage.