PAGE2OF4 650556Ć1

PARTS LIST / 650556-1

ITEM DESCRIPTION (Size in Inches) QTY PART NO. ITEM DESCRIPTION (Size In Inches) QTY PART NO.
1 Two Ball Piston Pump (1) 650685ĆP43
2 Cart Assembly (Includes Items 3 thru 14) (1) 67139
3Cotter Pin (3/32") (2) Y15Ć35ĆC
4 Washer (4) 91522
5Tip (2) 91011
6 Washer (3/8") (6) Y13Ć6ĆC
7 Screw (3/8" Ć 16 x 1Ć1/4") (4) Y6Ć66ĆC
8 Nut (3/8" Ć 16) (4) Y12Ć6ĆC
9 Wheel Assembly (2) 91515
10 Brace (1) 95102
11 Screw (5/16" Ć 18 x 3/4") (4) Y6Ć53ĆC
12 Nut (5/16" Ć 18) (4) Y12Ć5ĆC
13 Washer (5/16") (4) Y14Ć516ĆC
14 Cart Welding Assembly (1) 67138
15 Material Filter (Includes Item 16) (1) 651422Ć70
16 Plug (3/8") (1) Y17Ć13ĆS
17 Muffler (1) 91790ĆZZ
j18 3/4" Suction Hose Assembly (1) 622606Ć5
j19 90_Elbow (3/4") (1) Y43Ć15ĆS
j20 Suction Tube (5 Gallon) (1) 94263Ć1
21 Hose Assembly (1) 628092ĆF
22 Gauge (1) 100067
23 Modular Piggyback Filter/Regulator (1) P29241Ć100
24 Nipple (1/2" x 1Ć1/2" (m)) (1) Y27Ć54ĆC
25 Bushing (1/2" Ć 14 (m) x 1/4" Ć 18 (f)) (1) 94271
26 Nipple (1/4" Ć 18 (m)) (2) 1950
27 Street Tee (1/4" Ć 18) (1) 94270
28 Needle Valve (1) 94269
29 Adapter (1" (m) x 1/2" (f)) (1) 94256
30 90_Adapter (1" (m) x 1/4" (f) x 3/4" (f)) (1) 94254
31 Plug (1) Y17Ć11ĆS
jParts included in 67140Ć1 Asm (std)
Available: 67140Ć2 Asm. uses 94263Ć2 (36" Inlet Tube)

OPERATING INSTRUCTIONS

WARNING
DO NOT EXCEED MAXIMUM OPERATING PRESĆ
SURE OF 6000 P.S.I. (414 BAR) AT 100 P.S.I. (6.9 BAR) AIR INĆ
LET PRESSURE.
WARNING
REFER TO THE PUMP MANUAL FOR ADDITIONĆ
AL OPERATING AND SAFETY PRECAUTIONS AND OTHER
IMPORTANT INFORMATION.

INSTALLATION

OPERATING INSTRUCTIONS / INITIAL SETUP PROCEDURE
This unit comes assembled except for the air supply hose, gun and maĆ
terial hose which must be attached.
A connector, coupler and air supply hose and must be supplied
to the air regulator.
Attach a Ground wire to a suitable ground and the Ground Lug
provided on the pump Air Motor.
Keep containers covered to prevent contamination.
1. Turn the knob on the air regulator counterĆclockwise to zero p.s.i.
2. Attach hose and gun. Place pump inlet tube into a full container of
material.
3. Start the pump to cycle by turning the air regulator knob clockwise.
The pump will cycle several strokes until pressure is built up in the
system, at which time it will stall, check for any loose fittings or leakĆ
age. Check all connections and reĆtighten as necessary.
4. Relief Valve (28) is used to relieve pressure in the hose in order to
change spray tips. Open the relief valve to relieve pressure. Close
the relief valve to continue spray operation.