662420-B

INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, PARTS, TROUBLESHOOTING. RELEASED: 6-30-70

INCLUDE MANUALS: 6544X-X Air Motor (pn 97999-64) & S-632 General Information Manual (pn 97999-624).

REVISED: 3-12-09

 

(REV. N)

4-1/4” AIR MOTOR 9:1 RATIO

4” STROKE

662420-B

Basic Oil Pump

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

The original language of this manual is English.

SERVICE KITS

Use only genuine ARO® replacement parts to assure compat- ible pressure rating and longest service life.

61053 for repair of air motor and lower pump end.

61268 for repair of 65441-B air motor.

65823 packing kit assembly.

SPECIFICATIONS

Model Series (refer to option chart)

. . . . . 662420-B

Pump Type

Air Operated, Two-Ball Pump

Ratio

. . . . . 9:1

Air Motor

. . . . . 65441-B

Motor Repair Kit

. . . . . 61268

Motor Diameter

. . . . . 4-1/4” (10.8 cm)

Stroke (double acting)

. . . . . 4” (10.2 cm)

Air Inlet (female)

. . . . . 1/2 - 14 NPTF - 1

Air Exhaust (female)

. . . . . 1-1/4 - 11-1/2 NPTF - 1

Material Outlet (female)

. . . . . 3/4 - 14 NPTF

Lower Pump End

. . . . . 60873

Material Inlet (female)

. . . . . 2 - 11-1/2 NPT

Dimensional Data

. . . . . see figure 1

PUMP PERFORMANCE

Air Inlet Pressure Range

0

- 150 p.s.i.g. (0 - 10.3 bar)

Fluid Pressure Range

0

- 1350 p.s.i.g. (0 - 93.1 bar)

Maximum Rec'd Cycles / Minute . . .

. . .

. . . 75

Displacement In.3 Per Cycle

. . .

. . . 12.0

Volume / Cycle

. . .

. . . 6.65 oz. (196.8 ml)

Cycles Per Gallon

. . .

. . . 19.2

Maximum Working Flow Rate

. . .

. . . 3.9 g.p.m. (14.8 l.p.m.)

Noise Level @ 60 p.s.i. - 40 c.p.m.

. . . . . . 81.8 db(A)

Tested with 91790 silencer installed.

The pump sound pressure level has been updated to an Equivalent Continuous Sound Level (LAeq) to meet the intent of ANSI S1.13-1971, CAGI-PNEUROP S5.1 using four microphone locations.

GENERAL DESCRIPTION

The 9:1 ratio is an expression of the relationship between the effec- tive air motor area and the effective lower pump area. When 150 p.s.i. (10.3 bar) of air pressure is supplied to the air motor, the lower pump end will develop a maximum 1350 p.s.i. (93.1 bar) of fluid pressure (at no flow). As the fluid control is opened, the flow rate will increase as the air motor cycle rate increases to keep up with demand.

INGERSOLL RAND COMPANY LTD

P.O. BOX 151 ONE ARO CENTER BRYAN, OHIO 43506-0151

(800) 276-4658 FAX (800) 266-7016 © 2009CCN 81376725 fluids.ingersollrand.com

PUMP DATA

MODELS 662420-B

 

Air Exhaust (female)

 

1-1/4 - 11-1/2 NPTF - 1

 

Air Inlet (female)

 

1/2 - 14 NPTF - 1

“A”

65441-B Air Motor

(see manual 6544X-X)

662420-B Material Outlet (female)

3/4 - 14 NPTF

“B”

Figure 1

4-1/4” AIR MOTOR 9:1 RATIO Material Inlet (female)

2 - 11-1/2 NPT

NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only.

Model

“A” (mm)

“B” (mm)

662420-B

29” (736.4)

15-1/8" (383.9)

IMPORTANT

This is one of three documents which support the pump. Re- placement copies of these forms are available upon request.

662420-BModel Operator’s Manual (pn 97999-108)

S-632General Information - Air / Hydraulic Operated Piston Pumps (pn 97999-624)

6544X-XAir Motor Operator’s Manual (pn 97999-64)