OPERATOR’S MANUAL |
| |
|
| |
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE |
|
|
6” AIR MOTORS |
| 66620 |
|
| RELEASED: |
REVISED: | ||
4” STROKE | 6” STROKE | (REV. K) |
|
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
THIS MANUAL COVERS THE FOLLOWING MODELS
65643
65645
MODEL
65662 | 656652B | 66620 |
65665B | 65666 |
|
|
|
|
SERVICE KITS
61355 for general repair of all 6" air motors.
GENERAL DESCRIPTION
The 6" air motor is a general purpose power unit and is used with many 2ball, 4ball and chop check pumps. It utilizes tie rod type construction for easy breakdown and it connects to the various lower ends via tie rods for easy operation. Consult pump model operator's manual for specific instructions. It is recommended that a muffler be connected to the ex haust port to reduce noise to acceptable OSHA standards.
Filtered and oiled air will allow the air motor to operate more efficiently and yield a longer life to operating parts and mechanisms. A filter capa ble of filtering particles larger than 50 microns should be used with an oiler. Keep the oiler supplied with a good grade of S.A.E. no. 90W non detergent gear oil, set at a rate not to exceed 1 or 2 drops per minute.
NOTICE
DO NOT OPERATE AIR MOTOR ABOVE RECOMMENDED AIR PRESSURE OF 150 P.S.I. (10.3 BAR) OR 75 CYCLES PER MINUTE. Air motor may be rated differently in the next assembly. Check model plate.
P.O. BOX 151 D ONE ARO CENTER D BRYAN, OHIO 435060151
& (419)