Ingersoll-Rand 66650 manual 3” AIR MOTOR, Ratio, 2 1/4” STROKE, Pump Data, Operator’S Manual

Models: 66650

1 4
Download 4 pages 51.35 Kb
Page 1
Image 1
OPERATOR’S MANUAL

OPERATOR’S MANUAL

66650

 

 

INCLUDING:￿SERVICE KITS, GENERAL DESCRIPTION & TROUBLESHOOTING

ALSO INCLUDE MANUALS: 6641X-X AIR MOTOR MANUAL, FORM 3637-2 GENERALIN! FORMATION SHEET.

3” AIR MOTOR

BASIC PUMP

50:1 RATIO

66650

2 1/4” STROKE

35 LB DRUM

RELEASED: 6–23–95 (REV. A) IPP/PSE

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

 

 

SERVICE KITS

 

 

 

PUMP DATA

 

 

 

Use only genuine AROR replacement parts to assure compatible

 

 

 

 

 

 

 

 

 

 

 

 

pressure rating and longest service life.

 

 

 

 

 

 

637066-B for repair of Air Motor section.

 

 

 

 

 

 

Order individual parts for repair of Lower Pump section.

 

 

 

66410

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Motor

 

 

 

GENERAL DESCRIPTION

 

 

 

 

 

 

 

This model is designed for delivery of heavy viscosity fluids such as

 

 

 

 

 

 

chassis lubrication fluids. Material dispensing accessories and supply

 

 

 

1/2 NPT

 

 

lines and fittings must be capable of withstanding pressures developed

 

 

 

Mat’l Outlet

 

 

by pump.

 

 

 

 

 

 

The ARO 50:1 ratio basic pump assembly consists of a 3" air motor

 

28.5"

 

 

 

 

 

and lower pump end.

 

 

 

 

 

 

 

(723.9 mm)

 

 

 

 

 

 

 

 

 

 

 

RATIO x REGULATED AIR PRESSURE TO AIR MOTOR = MAXIMUM FLUID

 

 

 

 

 

 

 

 

PRESSURE.

 

 

 

 

 

 

The 50:1 ratio is an expression of the relationship between the air

 

20.2"

FIGURE 1

 

 

 

motor area and the lower pump end area. When 150 p.s.i. (10 bar)

 

 

 

 

 

 

 

 

 

 

 

(513.3 mm)

 

 

 

 

air pressure is supplied to the air motor, the lower pump end will

 

 

 

 

 

 

 

 

 

 

 

 

 

develop a maximum of 7,500 p.s.i. (517 bar) fluid pressure (at no

 

 

 

 

 

 

 

flow) - as the fluid control is opened, the flow rate will increase as

 

 

 

 

 

 

 

the air motor cycle rate increases to keep up with the demand.

 

 

 

Lower Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F031

Mat’l Inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATING AND SAFETY PRECAUTIONS

 

 

 

HEED ALL WARNINGS.

Do not operate pump continuously at speeds in excess of 75 cycles per min3

DO NOT EXCEED MAXIMUM WORKING PRESSURE OF 7,500 PSI (517

 

ute.

 

 

 

 

BAR) AT 150 PSI (10 BAR) AIR INLET PRESSURE.

 

WARNING

: PREVENT STATIC SPARKING. If static sparking

 

 

 

 

 

 

 

 

 

 

 

WARNING

: HIGH PRESSURE DEVICE. Improper usage of

 

occurs, fire or explosion could result. Pump, dispensing

 

this equipment could result in serious injury. The possibility

 

valve and containers must be grounded when handling in!

 

of injection into the flesh is a potential hazard. Never allow any

 

flammable fluids such as petroleum products, paints, lac!

 

part of the human body to come in front of or in direct contact

 

quers, etc. and wherever discharge of static electricity is a

 

with the material outlet. An injection injury can be serious. If

hazard.

 

 

 

 

injection should occur, contact a qualified physician immedi!

Use grounded hoses (static wire) and be sure the object is grounded if it can

 

ately for treatment.

 

produce a static charge.

 

 

 

COMPONENTRUPTURE. This pump is capable of producing high material

Use grounded hoses (static wire) and

be sure the object is

pressure as stated on pump model plate.

 

grounded if it can produce a static charge.

Be sure material hoses and other components are able to withstand fluid

Disconnect air line from pump air motor when system sits idle for long peri3

pressures developed by this pump.

ods of time.

 

THE ARO CORPORATION D ONE ARO CENTER D BRYAN, OHIO 43506–0151

&(419) 636–4242 D FAX (419) 636–2115

E1995 THE ARO CORPORATION D PRINTED IN U.S.A.

Page 1
Image 1
Ingersoll-Rand 66650 manual 3” AIR MOTOR, Ratio, 2 1/4” STROKE, Read This Manual Carefully Before Installing, Pump Data