OPERATOR’S MANUAL

66651-B

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

RELEASED: 1-21-00

 

 

REVISED: 8-1-11

10” AIR MOTOR

66651-B AIR MOTOR

(REV. F)

 

6” STROKE

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

yUse only genuine ARO® replacement parts to assure compatible pressure rating and longest service life.

y637110 service kit includes the necessary soft parts for normal service of the entire air motor.

y637111 service kit is a replacement valve kit.

GENERAL DESCRIPTION

The 10” air motor is a power unit used with a two-ball or chop-check pump. It utilizes tie rod construction for easy breakdown and it connects to the lower pump end with tie rods for easy operation. Consult the pump model operator’s manual for specific instructions.

OPERATING AND SAFETY PRECAUTIONS

DO NOT EXCEED MAXIMUM AIR INLET PRESSURE OF 90 P.S.I. (6.2 bar) OR 75 CYCLES PER MINUTE.

CAUTION: High pressure equipment - Always disconnect air supply and relieve material pressure before attempting to service.

A ground lug is located on the air motor. This ground lug al- lows proper grounding of the pump.

AIR AND LUBE REQUIREMENTS

A filter capable of filtering particles larger than 50 microns should be used with a lubricator.

Filtered and oiled air will allow the pump to operate more ef- ficiently and yield a longer life to operating parts and mecha- nisms.

Use an air line lubricator and keep it supplied with a good grade of S.A.E. #90W non-detergent gear oil set at a rate not to exceed approximately 1 drop per minute.