Page 8 of 8 66M3X0-XXX-C (en)
PN 97999-1398
CABDEFJHGL - Material outlet
M - Exhaust port
K - Air inlet
TROUBLE SHOOTING
Product discharged from exhaust outlet.
Check for diaphragm rupture.
Check tightness of (14) diaphragm screw.
Air bubbles in product discharge.
Check connections of suction plumbing.
Check “O” rings between intake manifold and uid caps.
Check tightness of (14) diaphragm screw.
y
y
y
y
y
Low output volume, erratic ow or no ow.
Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material hose.
Check for pump cavitation - suction pipe should be sized at
least as large as the inlet thread diameter of the pump for
proper ow if high viscosity uids are being pumped. Suction
hose must be a non-collapsing type, capable of pulling a high
volume.
Check all joints on the inlet manifolds and suction connections.
These must be air tight.
Inspect the pump for solid objects lodged in the diaphragm
chamber or the seat area.
y
y
y
y
y
y
y
DIMENSIONAL DATA
Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
Figure 5
DIMENSIONS
A - 22-7/32” (563.9 mm)
B - 26-13/16” (680.3 mm)
C - 11-1/8” (281.9 mm)
D - 2-3/4” (69.9 mm)
E - 16” (406.4 mm)
F - 11” (279.4 mm)
G - 32-5/8” (828.4 mm)
H - 30-11/32” (770.7 mm)
J - 18-25/32” (476.8 mm)
K - 3/4 - 14 NPTF - 2
L - see below
M - 1-1/4 - 11-1/2 NPTF - 2
“L”
66M300-XXX-C 3 - 8 NPTF - 2
66M320-XXX-C Rp 3 (3 - 11 BSP, parallel)