@35

 

41

 

PLACING TOOL IN SERVICE

LUBRICATION

Be sure all hoses and fittings are the correct size and are

 

tightly secured. See Dwg. TPD905-1 for a typical piping

 

arrangement.

IRAX No. 50

IRAX No. 100

Always use an air line lubricator with these tools.

We recommend the following Filter-Lubricator-Regulator Unit:

For USA - IRAX No. C31-06-G00

For International - IRAX No. FRL30-C6-A29

MAIN LINES

3 TIMES

AIR TOOL INLET SIZE

TO

 

AIR

I I

SYSTEM

After each eight hours of operation, unless an air line lubricator is used, inject approximately 1 to 2 cc of IRAX No. 50 Oil into the air inlet before attaching the air hose.

After each forty-eight hours of operation, or as experience indicates, inject about 4 cc of IR4X No. 100 Grease into the Grease Fitting (12).

INSTALLATION

Air Supply and Connections

Use clean, dry air at 90 psig maximum. Dust, corrosive fumes and/or excessive moisture can ruin the motor of an air tool. An air line filter can greatly increase the life of an air tool. The filter removes dust and moisture.

BRANCH LINE 2 TIMES

AIR TOOL INLET SIZE

DRAIN REGULARLY

COMPRESSOR

 

(Dwg. TPD905-1)

HOW TO ORDER AN IMPACT WRENCH

PISTOL GRIP with 3/4” SQUARE DRIVE

 

 

Recommended

Torque Range

Model

Impacts/min.

ft-lb

Nm

WG068A-F4

1000

200-600

271-813

3

Page 3
Image 3
Ingersoll-Rand WG068A-F4 manual Installation, HOW to Order AN Impact Wrench, Dwg. TPD905-1