Appendix- 85 -
Rebuilding an Array:
Rebuilding is the process of restoring data to a hard drive from other drives in the array. Rebuilding
applies only to fault-tolerant arrays such as RAID 1, RAID 10, or RAID 5 arrays. The procedures below
assume a new drive is added to replace a failed drive to rebuild a RAID 1 array.
Intel ICH10DO SATA controller:
Turn off your computer and replace the failed hard drive with a new one. Restart your computer.
Enabling Automatic Rebuild
Step 1:
When the message "Press <Ctrl-I> to enter Configuration Utility" appears, press <Ctrl> + <I> to enter the
RAID Configuration Utility. The following screen appears after you enter the RAID Configuration Utility.
Intel(R) Matrix Storage Manager option ROM v8.5.0.1030 ICH10R/DO wRAID5
Copyright(C) 2003-08 Intel Corporation. All Rights Reversed.
[ MAIN MENU ]
1.Create RAID Volume
2.Delete RAID Volume
[ DISK/VOLUME INFORMATION ]
RAID Volumes :
None defined.
Physical Disks :
Port Drive Model Serial # Size Type/Status(Vol ID)
0 WDC WD800JD-22LSWD-WMAM9W736201 74.4GB Member Disk (0)
1 WDC WD800JD-22LSWD-WMAM9W736333 74.4GB Non-RAID Disk
[]-Select [ESC]-Exit [ENTER]-Select Menu
3. Reset Disks to Non-RAID
4. Exit
[ DEGRADED VOLUME DETECTED ]
"Degraded volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
1 WDC WD800JD-22LS WD-WMAM9W736333 74.4GB
[]-Previous/Next [ENTER]-Select [ESC]-Exit
Intel(R) Matrix Storage Manager option ROM v8.5.0.1030 ICH10R/DO wRAID5
Copyright(C) 2003-08 Intel Corporation. All Rights Reversed.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION ]
RAID Volumes :
ID Name Level Strip Size Status Bootable
0 gbb RAID1(Mirror) N/A 74.4GB Rebuild Yes
Physical Disks :
Port Drive Model Serial # Size Type/Status(Vol ID)
0 WDC WD800JD-22LSWD-WMAM9W736201 74.4GB Member Disk (0)
1 WDC WD800JD-22LSWD-WMAM9W736333 74.4GB Member Disk (0)
[]-Select [ESC]-Exit [ENTER]-Select Menu
1.Create RAID Volume
2.Delete RAID Volume 3. Reset Disks to Non-RAID
4. Exit
Volumes with "Rebuild" status will be rebuilt within the operating system.
Step 2:
Select the new hard drive to add into the array to be rebuilt and press <Enter>. The following screen
appears, indicating that an automatic rebuild will be performed automatically after you enter the
operating system (look for the Intel Storage Console icon in the notification area, which will show
that a RAID volume is being rebuilt). If you do not enable automatic rebuild on this stage, you have to
manually rebuild the array in the operating system (see the next for more details).