100 Intel® Server System SR1680MV Service Guide
Figure 65. Location Of Spring Screw Holes
Table 43. Location and Adapt Depth for Racks
Procedure to install the rail kit
Note: Please follow the steps below before you install the rail:
1. To avoid a potential electrical shock hazard, a third wire safety grounding
conductor is necessary for the rack installation.
2. The equipment rack must provide sufficient airflow to the system to maintain
proper cooling.
Procedure:
1. Put the tighten screws2 into the washers.
2. Install the tighten screws2 with washers into the hole of the rails (Recommended
Driver Force: 5 lb-in).
Sprong Secure Hole Adapt Depth For Racks
HOLE 1 782.0~794.5 mm
HOLE 2 769.5~782.0 mm
HOLE 3 757.0~769.5 mm
HOLE 4 744.5~757.0 mm
HOLE 5 732.0~744.5 mm
HOLE 6 719.5~732.0 mm
HOLE 7 707.0~719.5 mm