WARNING

Inspect power cord, plug, or air hoses of the Invacare APP Alternating Pressure Pump for breaks, tears, or kinks. If damage is found, DO NOT use.

DO NOT, under any circumstances, cut or remove the round grounding prong from any plug used with or for Invacare products. Some devices are equipped with three- prong (grounding) plugs for protection against possible shock hazards. Where a two- prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to contact a qualified electrician and have the two-prong receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code. If you must use an extension cord, use only a three-wire extension cord having the same or higher electrical rating as the device being connected.

Ensure that the pad is brought up to room temperature before unfolding.

DO NOT place hot objects such as heating pads on top of the pad. This may weaken the pad material and may cause injury.

Use extreme care when handling sharp objects such as needles near the pad.

WARNING

The pad has a weight limitation of 250 lbs (114 kg).

NOTE: Check ALL parts for shipping damage. If shipping damage is noted, DO NOT use. Contact carrier/dealer for further instruction.

3 Usage

NOTE: For this section, refer to FIGURE 1 on page 3.

3.1Installing the APP

1.Perform one of the following:

A.Place the Invacare APP Alternating Pressure Pump on a flat surface near the bed.

B.Open the hooks on the back of the Invacare APP Alternating Pressure Pump and install on the outside of the bed frame as shown in Detail A.

2.Place pad on top of bed mattress.

NOTE: Air chamber openings should be at bed end.

3.Install end flaps over mattress corners to secure pad.

4.Connect the other end of air hoses to the pump (Detail B).

5.Connect air hoses with fittings to the air chamber openings on the pad.

6.Install sheet over pad and bed mattress.

7.Use the pump. Refer to Using the Pump on page 2.

3.2Using/Adjusting the Pump

Using the Pump

1.Plug power cord into outlet.

2.Turn power switch to the ON position (Detail C).

APP Alternating Pressure Pump

2

Part No 1164942

Page 2
Image 2
Invacare CG9701 user manual Usage, Installing the APP, Using/Adjusting the Pump Using the Pump

CG9701 specifications

The Invacare CG9701 is an advanced and versatile power wheelchair designed to enhance mobility and independence for users with varying physical capabilities. This model combines innovative technology with comfort, ensuring an outstanding experience for its users. The CG9701 is tailored for both indoor and outdoor use, making it an ideal choice for those who seek a reliable mobility solution.

One of the standout features of the Invacare CG9701 is its powerful and efficient drive system, which includes robust motors that provide excellent performance on different terrains. Users can navigate various surfaces, from smooth indoor floors to rough outdoor paths, with ease. The chair's remarkable speed control allows for smooth acceleration and deceleration, ensuring a safe driving experience.

The CG9701 is equipped with an ergonomic seating system, which includes adjustable armrests and footrests. This adaptability caters to individual preferences, promoting comfort during prolonged use. The seat itself can be adjusted in height and depth, accommodating users of different sizes and providing the necessary support for hours of sitting.

The Invacare CG9701 also incorporates advanced technology in its control systems. The joystick controller is intuitive, allowing users to operate the wheelchair with minimal effort. The controller features programmable settings, enabling users to customize speed and sensitivity based on their personal needs and capabilities. Furthermore, the chair includes safety features such as anti-tip wheels and a secure braking system, ensuring stability and peace of mind during operation.

Durability is a key characteristic of the CG9701. It features a rugged frame that withstands daily wear and tear, making it suitable for regular use without compromising aesthetics or functionality. The high-quality materials used in its construction guarantee longevity, even in demanding environments.

The wheelchair's battery system is another highlight, offering an extended range that allows users to travel further without the worry of running out of power. The charging system is designed for convenience, and users can easily recharge the batteries at home or in accessible public spaces.

Overall, the Invacare CG9701 stands out in the mobility market due to its combination of comfort, customization, and cutting-edge technology. It provides users with the freedom to navigate their environments confidently, making it a valuable investment for those seeking enhanced mobility and independence.