Jackson HH/GPX Amps, Dimensions--Standard Model, Dimension Requirements, Gas Requirements

Models: HH/GPX

1 2
Download 2 pages 53.68 Kb
Page 2
Image 2
DIMENSIONS--STANDARD MODEL

4 [102mm]

4 [102mm]

 

3 [77mm]

C

 

251

[642mm]

4

 

32 [813mm]

DIMENSIONS--STANDARD MODEL

 

 

 

25 [637mm]

 

 

 

LEGEND

 

 

251

[639mm]

 

 

 

 

17 [432mm]

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

A - DRAIN 1 1/2” NPT

 

 

3 [79mm]

 

 

 

 

 

 

 

 

B - WATER INLET 1/2” NPT

 

 

 

 

 

 

 

 

 

 

 

 

C - ELECTRICAL CONNECTION

 

 

 

 

3

 

 

 

 

 

 

D - OUTLET TO BOOSTER

 

 

 

C

 

[2202mm]

 

 

 

 

 

HEATER 3/4” NPT

 

 

 

 

864

C

 

 

 

 

E - INLET FROM BOOSTER

 

 

 

 

 

 

 

 

 

 

 

 

HEATER 3/4” NPT

 

 

 

 

 

 

 

 

 

 

 

 

All vertical dimensions are +/- 1/2"

 

 

 

 

 

 

 

 

 

 

 

due to adjustable bullet feet.

 

 

 

 

 

 

73 [1856mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27 [687mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34 [866mm]

 

 

 

 

 

 

 

 

D

 

 

 

B

 

 

 

A

 

 

34 [861mm]

 

 

 

 

18 [456mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

3

[426mm]

 

 

 

 

 

3

 

[298mm]

164

 

 

 

 

 

[194mm]

11

4

 

 

 

 

 

 

 

7

 

 

 

 

 

 

A

 

 

 

4

 

E

 

 

 

 

 

 

E

 

 

 

 

1 [25mm]

31

[92mm]

 

5 [126mm]

 

 

3

[298mm]

 

 

 

 

 

2

 

 

 

 

11

 

 

 

 

3

[274mm]

 

 

1

 

4

 

 

 

 

104

 

 

 

 

 

 

 

 

 

 

 

 

 

 

154

[387mm]

 

model no.

 

size

 

Drain

shipping info

 

 

dimensions

 

 

 

 

 

 

 

 

 

 

 

height

width

DEPTH

weight

class

 

cube

height

width

depth

 

height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TempStar™ HH/GPX

76-3/4”

25-1/4”

25-1/4”

11-3/4”

420 lbs

92.5

 

71.4

85”

44”

33”

(1949 mm)

(641 mm)

(641 mm)

(298 mm)

(191 kg)

 

 

cu. ft.

(2159 mm)

(1118 mm)

(838 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSION REQUIREMENTS

Minimum Ceiling Height (Recommended)

88” / (2 meters)

 

 

Wall Clearance (Minimum)

4” / (102 mm)

 

 

Standard Table Height

34” / (864 mm)

 

 

Inside Clearance

17-1/4”/ (438 mm)

 

 

GAS REQUIREMENTS

 

Maximum

Minimum

 

 

 

Natural Gas (Inches-water column)

10.5 / (267 mm)

5.0 / (127 mm)

 

 

 

LP Propane Gas (Inches-water column)

13.0 / (330 mm)

11.0 / 292 mm)

 

 

 

Gas Booster Capacity (BTU)

 

 

 

 

 

Input

 

105,000

 

 

 

Output

 

84,800

 

 

 

OPERATING CAPACITY

Racks per Hour

Normal

Medium

Heavy

Extra Heavy

53

28

19

11

 

 

 

 

 

 

OPERATING CYCLE (sec)

Wash

Rinse

Dwell

Total Cycle

 

 

 

 

 

Normal

45

15

2

62

 

 

 

 

 

Medium

103

15

2

120

 

 

 

 

 

Heavy

163

15

2

180

 

 

 

 

 

Extra Heavy

283

15

2

300

 

 

 

 

 

OPERATING TEMPERATURES

 

 

 

 

 

 

 

Wash (Minimum)

 

 

150˚F / (66˚C)

 

 

 

 

Rinse (Minimum)

 

 

180˚F / (82˚C)

 

 

 

 

 

WASH PUMP MOTOR

 

 

 

 

 

 

 

 

Wash Pump Motor Horsepower

 

 

2 HP

 

 

 

 

 

How To Specify - TempStar™ HH/GPX

WATER REQUIREMENTS

Inlet Tempterature

40˚F / (4˚C) Rise

140˚F / (82˚C)

 

 

70˚F / (21˚C) Rise

110˚F / (60˚C)

 

 

Gallons per hour

72.1 / 273 Ltr.

 

 

Waterline Size IPS (Minimum-inches)

3/4

 

 

Drainline Size IPS (Minimum-Inches)

1-1/2

 

 

Flow Pressure (PSI)

15-25

 

 

Tank Capacity

 

 

 

Wash Tank

8 Gal. / (30 ltr)

 

 

Booster Tank

3 Gal. / (11 ltr)

 

 

Pump Capacity (GPM)

73 Gal / (276 ltr)

 

 

APPROXIMATE TOTAL LOAD AMPS

 

AMPS

 

 

115V/60HZ/1PH

25

 

 

208V/60HZ/1PH

13

 

 

230V/60HZ/3PH

13

 

 

230V/60HZ/1PH

13

 

 

230V/60HZ/3PH

13

 

 

Highway 25E

 

Tel: 606-523-9795

 

www.jacksonmsc.com

 

 

P. O. Box 1060

 

Tel: 1-888-800-5672

 

07610-002-66-62 (09/07)

Barbourville, KY 40906

 

Fax: 606-523-9196

 

 

 

 

E-mail: info@jacksonmsc.com

 

 

 

 

 

 

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

Page 2