Jackson TempStar b Dimensions--Standard Model, Dimension Requirements, Operating Capacity, Volts

Models: TempStar b

1 2
Download 2 pages 51.24 Kb
Page 2
Image 2
DIMENSIONS--STANDARD MODEL

 

 

 

251

[639mm]

 

 

 

 

25 [637mm]

 

LEGEND

 

 

 

 

 

 

17 [432mm]

 

 

 

4

 

 

 

 

 

 

 

 

 

3 [79mm]

1 [27mm]

 

 

 

 

 

A - DRAIN 1 1/2" IPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B - WATER INLET 3/4" IPS

 

 

 

C

B

863

[2202mm]

C

B

 

C - ELECTRICAL CONNECTION

 

 

 

 

4

 

 

 

All vertical dimensions are +/- 1/2" due to

 

 

 

 

 

 

 

 

 

adjustable bullet feet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

73 [1856mm]

731

[1863mm]

 

 

 

 

 

 

 

 

 

4

 

4 [101mm]

 

 

 

 

 

 

 

 

27 [687mm]

 

B

 

 

 

 

 

 

 

 

 

3 [76mm]

 

 

 

 

 

 

 

 

 

 

A

4 [102mm]

 

 

 

 

 

 

 

34 [861mm]

 

 

 

 

 

 

 

 

 

 

3

[298mm]

 

 

 

 

 

 

 

 

 

114

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

151

[387mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS--STANDARD MODEL

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIZE

 

DRAIN

 

 

SHIPPING INFO

 

 

 

 

 

DIMENSIONS

 

MODEL NO.

 

 

 

HEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT

WIDTH

DEPTH

 

WEIGHT

 

CLASS

 

CUBE

HEIGHT

 

WIDTH

DEPTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TempStar™HH

76-3/4”

25-1/4”

25-1/4”

11-3/4”

 

 

420 lbs

92.5

 

71.4

 

 

85”

 

 

44”

33”

(1949 mm)

(641 mm)

(641 mm)

(298 mm)

 

(191 kg)

 

 

 

cu. ft.

(2159 mm)

(1118 mm)

(838 mm)

 

 

 

 

 

DIMENSION REQUIREMENTS

Minimum Ceiling Height (Recommended)

88” / (2 meters)

 

 

Wall Clearance (Minimum)

4” / (102 mm)

 

 

Standard Table Height

34” / (864 mm)

 

 

Inside Clearance

17-1/4” / (438 mm)

 

 

OPERATING CAPACITY

Racks per Hour

 

Normal

Medium

Heavy

Extra Heavy

 

 

53

28

19

11

 

 

 

 

 

 

OPERATING CYCLE (sec)

 

Wash

Rinse

Dwell

Total Cycle

 

 

 

 

 

 

Normal

 

45

15

2

62

 

 

 

 

 

 

Medium

 

103

15

2

120

 

 

 

 

 

 

Heavy

 

163

15

2

180

 

 

 

 

 

 

Extra Heavy

 

283

15

2

300

 

 

 

 

 

 

OPERATING TEMPERATURES

 

 

 

 

 

 

 

 

 

 

Wash (Minimum)

 

 

 

150˚F / (66˚C)

 

 

 

 

 

Rinse (Minimum)

 

 

 

180˚F / (82˚C)

 

 

 

 

 

WASH PUMP MOTOR

 

 

 

 

 

 

 

 

 

Wash Pump Motor Horsepower

 

 

 

2 HP

 

 

 

 

 

 

 

 

 

 

Volts

KW

 

 

 

 

 

Electric Wash Tank Heater

 

 

208V

4.1

 

 

 

 

 

 

 

 

 

 

230V

5.0

 

 

 

 

 

 

 

 

 

 

460V

5.0

 

 

 

 

Electric Rinse Tank Heater

40˚F (4˚C) Rise

208V

9.0

 

 

 

 

 

 

 

 

 

 

230V

11.0

 

 

 

 

 

 

 

 

 

 

460V

11.0

 

 

 

 

 

 

 

70˚F (21˚C) Rise

208V

10.5

 

 

 

 

 

 

 

 

 

 

230V

12.9

 

 

 

 

 

 

 

 

 

 

460V

12.9

 

 

 

 

 

 

STEAM REQUIREMENTS

Steam Flow Pressure (PSIG)

15-20

 

 

Consumption @ 15 PSIG (lbs/hr)

45

 

 

WATER REQUIREMENTS

Inlet Tempterature

40˚F / (4˚C) Rise

140˚F / (82˚C)

 

 

70˚F / (21˚C) Rise

110˚F / (60˚C)

 

 

Gallons per hour

72.1 / 273 Ltr.

 

 

Gallons per rack

1.36 / 5 Ltr

 

 

Waterline Size IPS (Minimum-inches)

3/4

 

 

Drainline Size IPS (Minimum-Inches)

1-1/2

 

 

Waterline Flow Rate (GPM)

5.44

 

 

Flow Pressure (PSI)

15-25

 

 

Tank Capacity

3 gals / (11 ltrs)

 

 

Wash Tank

8 Gal. / (30 ltr)

 

 

Booster Tank

3 Gal. / (11 ltr)

 

 

APPROXIMATE LOAD AMPS

 

No Booster

40˚F (4˚C) Rise

70˚F (21˚C) Rise

 

 

 

 

Power Supply

AMPS

AMPS

AMPS

 

 

 

 

208V/60HZ/1PH

31

74.2

81.4

 

 

 

 

208V/60HZ/3PH

23

47.6

51.8

 

 

 

 

230V/60HZ/1PH

33

80.9

89.0

 

 

 

 

230V/60HZ/3PH

24

51.4

56.2

 

 

 

 

460V/60HZ/3PH

10

23.4

25.8

 

 

 

 

How To Specify - TempStar™ HH

SHIPPING ADDRESS

6209NorthU.S.Highway25E Gray, KY 40734

MAILING ADDRESS

P. O. Box 1060

Barbourville, KY 40906

Tel: 606-523-9795

Tel: 1-888-800-5672

Fax: 606-523-1799

www.jacksonmsc.com

E-mail: customerservice@jacksonmsc.com 07610-002-66-60B (11/08)

Page 2
Image 2
Jackson TempStar b Dimensions--Standard Model, Dimension Requirements, Operating Capacity, Wash Pump Motor, Volts, Drain