251

[639mm]

 

 

 

 

25 [637mm]

 

LEGEND

 

 

 

 

 

 

17 [432mm]

 

 

 

4

 

 

 

 

 

 

 

 

 

3 [79mm]

1 [27mm]

 

 

 

 

 

A - DRAIN 1 1/2" IPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B - WATER INLET 3/4" IPS

 

 

 

C

B

863

[2202mm]

C

B

 

C - ELECTRICAL CONNECTION

 

 

 

 

4

 

 

 

All vertical dimensions are +/- 1/2" due to

 

 

 

 

 

 

 

 

 

adjustable bullet feet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

73 [1856mm]

731

[1863mm]

 

 

 

 

 

 

 

 

 

4

 

4 [101mm]

 

 

 

 

 

 

 

 

27 [687mm]

 

B

 

 

 

 

 

 

 

 

 

3 [76mm]

 

 

 

 

 

 

 

 

 

 

A

4 [102mm]

 

 

 

 

 

 

 

34 [861mm]

 

 

 

 

 

 

 

 

 

 

3

[298mm]

 

 

 

 

 

 

 

 

 

114

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

151

[387mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS--STANDARD MODEL

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

size

 

Drain

 

 

shipping info

 

 

 

 

 

dimensions

 

model no.

 

 

 

height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

height

width

DEPTH

 

weight

 

class

 

cube

height

 

width

depth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TempStar™HH

76-3/4”

25-1/4”

25-1/4”

11-3/4”

 

 

420 lbs

92.5

 

71.4

 

 

85”

 

 

44”

33”

(1949 mm)

(641 mm)

(641 mm)

(298 mm)

 

(191 kg)

 

 

 

cu. ft.

(2159 mm)

(1118 mm)

(838 mm)

 

 

 

 

 

DIMENSION REQUIREMENTS

Minimum Ceiling Height (Recommended)

88” / (2 meters)

 

 

Wall Clearance (Minimum)

4” / (102 mm)

 

 

Standard Table Height

34” / (864 mm)

 

 

Inside Clearance

17-1/4” / (438 mm)

 

 

OPERATING CAPACITY

Racks per Hour

 

Normal

Medium

Heavy

Extra Heavy

 

 

53

28

19

11

 

 

 

 

 

 

OPERATING CYCLE (sec)

 

Wash

Rinse

Dwell

Total Cycle

 

 

 

 

 

 

Normal

 

45

15

2

62

 

 

 

 

 

 

Medium

 

103

15

2

120

 

 

 

 

 

 

Heavy

 

163

15

2

180

 

 

 

 

 

 

Extra Heavy

 

283

15

2

300

 

 

 

 

 

 

OPERATING TEMPERATURES

 

 

 

 

 

 

 

 

 

 

Wash (Minimum)

 

 

 

150˚F / (66˚C)

 

 

 

 

 

Rinse (Minimum)

 

 

 

180˚F / (82˚C)

 

 

 

 

 

WASH PUMP MOTOR

 

 

 

 

 

 

 

 

 

Wash Pump Motor Horsepower

 

 

 

2 HP

 

 

 

 

 

 

 

 

 

 

Volts

KW

 

 

 

 

 

Electric Wash Tank Heater

 

 

208V

4.1

 

 

 

 

 

 

 

 

 

 

230V

5.0

 

 

 

 

 

 

 

 

 

 

460V

5.0

 

 

 

 

Electric Rinse Tank Heater

40˚F (4˚C) Rise

208V

9.0

 

 

 

 

 

 

 

 

 

 

230V

11.0

 

 

 

 

 

 

 

 

 

 

460V

11.0

 

 

 

 

 

 

 

70˚F (21˚C) Rise

208V

10.5

 

 

 

 

 

 

 

 

 

 

230V

12.9

 

 

 

 

 

 

 

 

 

 

460V

12.9

 

 

 

 

 

 

STEAM REQUIREMENTS

Steam Flow Pressure (PSIG)

15-20

 

 

Consumption @ 15 PSIG (lbs/hr)

45

 

 

WATER REQUIREMENTS

Inlet Tempterature

40˚F / (4˚C) Rise

140˚F / (82˚C)

 

 

70˚F / (21˚C) Rise

110˚F / (60˚C)

 

 

Gallons per hour

72.1 / 273 Ltr.

 

 

Gallons per rack

1.36 / 5 Ltr

 

 

Waterline Size IPS (Minimum-inches)

3/4

 

 

Drainline Size IPS (Minimum-Inches)

1-1/2

 

 

Waterline Flow Rate (GPM)

5.44

 

 

Flow Pressure (PSI)

15-25

 

 

Tank Capacity

3 gals / (11 ltrs)

 

 

Wash Tank

8 Gal. / (30 ltr)

 

 

Booster Tank

3 Gal. / (11 ltr)

 

 

APPROXIMATE LOAD AMPS

 

40˚F (4˚C) Rise

70˚F (21˚C) Rise

 

 

 

Power Supply

AMPS

AMPS

 

 

 

208V/60HZ/1PH

74.2

81.4

 

 

 

208V/60HZ/3PH

47.6

51.8

 

 

 

230V/60HZ/1PH

80.9

89.0

 

 

 

230V/60HZ/3PH

51.4

56.2

 

 

 

460V/60HZ/3PH

23.4

25.8

 

 

 

How To Specify - TempStar™ HH

Highway 25E

 

Tel: 606-523-9795

 

www.jacksonmsc.com

 

 

P. O. Box 1060

 

Tel: 1-888-800-5672

 

07610-002-66-60B (09/07)

Barbourville, KY 40906

 

Fax: 606-523-9196

 

 

 

 

E-mail: info@jacksonmsc.com

 

 

 

 

 

 

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

Page 2
Image 2
Jackson TempStar HH specifications DIMENSIONS--STANDARD Model, Dimension Requirements, Operating Capacity, Wash Pump Motor

TempStar HH specifications

The Jackson TempStar HH is a highly regarded heating and cooling system celebrated for its impressive efficiency and reliability. As part of the TempStar brand, which is well-known for its commitment to quality HVAC products, the Jackson TempStar HH promises homeowners comfortable indoor climates whether in the scorching summer heat or during icy winter temperatures.

One of the primary features of the Jackson TempStar HH is its Energy Star certification, which signifies that the system meets stringent energy efficiency guidelines set by the U.S. Environmental Protection Agency. This efficiency not only reduces utility bills but also minimizes the environmental impact, making it a smart choice for eco-conscious consumers. With a high Seasonal Energy Efficiency Ratio (SEER) rating, the air conditioning component excel in energy use, providing consistent performance even during the hottest days.

The Jackson TempStar HH system is armed with innovative technologies designed to enhance its effectiveness and user experience. One notable technology is the variable-speed blower motor, which enables the system to adjust airflow according to the home's specific needs. This results in quieter operation and improved comfort, as the system can maintain a steady temperature without frequent on-and-off cycling.

In terms of design and construction, the Jackson TempStar HH features a durable cabinet that is built to withstand harsh weather conditions while minimizing noise levels. Its compact and aesthetically pleasing design ensures that the unit can fit seamlessly within the residential landscape without compromising curb appeal.

Another significant characteristic of the Jackson TempStar HH is its advanced control system, which often includes programmable thermostats that allow users to set schedules for heating and cooling. This feature not only maximizes comfort but also further enhances energy efficiency by ensuring systems operate only when needed.

Moreover, the Jackson TempStar HH often includes a range of additional features such as smart home compatibility, allowing users to control their heating and cooling remotely. This integration with home automation systems provides convenience while enhancing energy management.

Overall, the Jackson TempStar HH is a robust heating and cooling solution, characterized by its energy efficiency, innovative technologies, and user-centric features. It continues to be a preferred choice for homeowners seeking reliable climate control in their living spaces, aligning performance with sustainability.