Unit shall have the following features:

TS-66 Traditional

Series

Conveyors

 

Specifications

Note: Check and/or copy all that apply.

TS-66 Series Rack Conveyor Dishwasher—Item No. ____________

Unit shall have the following features:

Shall be a Jackson TS-66 series, single tank rack conveyor dishwasher. Sanitization shall be accomplished by using:

______ Hi-temp (180°F minimum) sanitizing rinse

Electrical characteristics shall be:

______ 208V/60HZ/3PH

______ 208V/50HZ/3PH

______ 208V/60HZ/1PH

______ 208V/50HZ/1PH

______ 230V/60HZ/3PH

______ 230V/50HZ/3PH

______ 230V/60HZ/1PH

______ 230V/50HZ/1PH

______ 460V/60HZ/3PH

 

Wash tank heating shall be a minimum of 160°F for hi-temp applications and accomplished by:

______ 15 KW electric heating elements thermostatically controlled.

______ Stainless steel steam coils thermostatically controlled.

Direction of rack flow shall be (when standing in front of machine):

______ Right-to-Left

______ Left-to-Right

Unit shall have the following features as optional extras:

252 racks per hour utilizing 0.74 gallons of water per rack for hi-temp sanitizing rinse.

Incoming water pressure regulator.

Standard 18" clearance throughout machine.

Exclusive “Energy Guard” con- trols system energizes prewash, wash, recirculating rinse, and final rinse sections only when a rack is in place.

Completely electro-mechanical; no solid-state controls.

Fully automatic operation includ- ing auto-fill.

Stainless steel wash pump and impeller and completely self-draining.

Wash section must be a mini- mum of 16” in length as well as 18” separation between recircu- lating wash and final rinse.

Convenient, externally operated lever drain.

Vent cowls/splash shields with extra curtains on both wash and rinse ends of the machine.

Stainless steel frame, legs, adjustable bullet feet, and front appearance panel.

All 304 series stainless steel construction; no 400 series stainless steel and no plastics utilized.

______ External electric 24 KW booster heater for a minimum 40°F rise

and available in the following voltages:

______ 208V/50 or 60HZ/3PH

______ 240V/50 or 60HZ/3PH

______ 480V/50 or 60HZ/3PH

______ External electric 36 KW booster heater for a minimum 70°F rise

and available in the following voltages:

______ 208V/50 or 60HZ/3PH

______ 240V/50 or 60HZ/3PH

______ 480V/50 or 60HZ/3PH

______ Steam booster heater.

______ Exhaust fan control controls external exhaust fan power and

duration time.

______ Flanged feet for permanent in-place mounting to the floor.

______ Table limit switch completely prewired and extending from the

output end of the machine, 15’0” long.

______ Whisker-style switch

______ Striker plate switch

______ Photosensor switch

______ Installed 4" x 16" x 7" high vent cowl collars for easy connection

to an external exhaust system and including adjustable and lock-

able damper flaps.

 

______ output end only

______ input end only

______ both ends

 

______ Incoming water hammer arrestor installed.

______ Sideloader installed on input end of machine.

______ unhooded sideloader

______ hooded sideloader