Series | Conveyors |
|
Specifications
Note: Check and/or copy all that apply.
Unit shall have the following features:
Shall be a Jackson
______
Electrical characteristics shall be:
______ 208V/60HZ/3PH | ______ 208V/50HZ/3PH |
______ 208V/60HZ/1PH | ______ 208V/50HZ/1PH |
______ 230V/60HZ/3PH | ______ 230V/50HZ/3PH |
______ 230V/60HZ/1PH | ______ 230V/50HZ/1PH |
______ 460V/60HZ/3PH |
|
Wash tank heating shall be a minimum of 160°F for
______ 15 KW electric heating elements thermostatically controlled.
______ Stainless steel steam coils thermostatically controlled.
Direction of rack flow shall be (when standing in front of machine):
______ | ______ |
Unit shall have the following features as optional extras:
•252 racks per hour utilizing 0.74 gallons of water per rack for
•Incoming water pressure regulator.
•Standard 18" clearance throughout machine.
•Exclusive “Energy Guard” con- trols system energizes prewash, wash, recirculating rinse, and final rinse sections only when a rack is in place.
•Completely
•Fully automatic operation includ- ing
•Stainless steel wash pump and impeller and completely
•Wash section must be a mini- mum of 16” in length as well as 18” separation between recircu- lating wash and final rinse.
•Convenient, externally operated lever drain.
•Vent cowls/splash shields with extra curtains on both wash and rinse ends of the machine.
•Stainless steel frame, legs, adjustable bullet feet, and front appearance panel.
•All 304 series stainless steel construction; no 400 series stainless steel and no plastics utilized.
______ External electric 24 KW booster heater for a minimum 40°F rise
and available in the following voltages:
______ 208V/50 or 60HZ/3PH
______ 240V/50 or 60HZ/3PH
______ 480V/50 or 60HZ/3PH
______ External electric 36 KW booster heater for a minimum 70°F rise
and available in the following voltages:
______ 208V/50 or 60HZ/3PH
______ 240V/50 or 60HZ/3PH
______ 480V/50 or 60HZ/3PH
______ Steam booster heater.
______ Exhaust fan control controls external exhaust fan power and
duration time.
______ Flanged feet for permanent
______ Table limit switch completely prewired and extending from the
output end of the machine, 15’0” long.
______
______ Striker plate switch
______ Photosensor switch
______ Installed 4" x 16" x 7" high vent cowl collars for easy connection
to an external exhaust system and including adjustable and lock-
able damper flaps. |
|
______ output end only | ______ input end only |
______ both ends |
|
______ Incoming water hammer arrestor installed.
______ Sideloader installed on input end of machine.
______ unhooded sideloader | ______ hooded sideloader |
www.jacksonmsc.com