J-200
GRN
WHT
WHT
BLK
BLK
BLK
RED
1
2
3
Figure-C TB1
to Circuit
Board
Power In
GRN
WHT WHT
BLK
BLK
BLK
RED RED
RED
1
2
3
Figure-D TB1
to Circuit
Board
Power In
Move Red
Wire Here

north american Convertible

models: 120 VAC, 3-Wire Connection

60 Hz

north american Convertible

models: 240 VAC, 4-Wire Connection

60 Hz

CauTIon (For 4-wire 240 vaC Heater operation): move the red wire on the main terminal strip (TB1) from position #1 to position #3. make certain wires are connected exactly as shown in Figure D before applying power. Failure to do so will result in damage to the circuit board and/or related components and void the manufacturer’s warranty.
BLK
RED
RED
RED
BLK
BLK
1
2
Figure-E TB1

to Circuit

Board

Power In

Green
TB3
1
2
BLUE
BLUE
BROWN
BROWN
Figure-F TB1

to Circuit

Board

Power In

Green
TB3

north american 240v models:

240 VAC, 3-Wire Connection 60 Hz

all export models: 230 VAC, 3-Wire

Connection 50 Hz

Congratulations! You are now all set to get your new spa ready to use. Simply follow the step-by-step procedure in Section 8.0, before long, you will be enjoying your î‚¿rst glorious experience in your Jacuzzi J-200 Collection spa.