J-200
6.0 power requirements
Jacuzzi spas are designed to provide optimum performance and
exibility of use when connected to the maximum electrical service listed
below. Minor circuit board modications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
note: Refer to pages 44-47 for circuit board conguration details or
contact your authorized Jacuzzi dealer.
all north american J-270 and J-280 models (60 Hz)
240V/40A* 240V/50A** 240V/60A***
Circuit Breaker (2-Pole): 40A*50A** 60A***
Number of Wires: 3 3 3
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 26A 36A 45A
* In 40A conguration, the heater will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high
speed.
** In 50A conguration, the heater will not operate while both jets
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
*** In 60A conguration the heater will operate while both jets pumps
are running in high speed.
all north american J-230 models (60 Hz)
240V/40A* 240V/50A**
Circuit Breaker (2-Pole): 40A*50A**
Number of Wires: 3 3
Frequency: 60 Hz 60 Hz
Current Draw: 26A 36A
* In 40A conguration, the heater will not operate while the jets
pump is running in high speed.
** In 50A conguration, the heater will operate while the jets pump is
running in high speed. This is the factory setting.
13