Single, Dual and Triple

Single, Dual and Triple

 

Gang Boxes

Tabs

When installing the 45609 in multiple gang boxes it may be necessary to break off one or both of the scored tabs on the front yoke. This does not affect the electrical rating of the 45609.

Tabs

Break at this line

Gang Boxes WARNING - SHOCK HAZARD

Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel. All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the switch.

1.Shut off power to the circuit at fuse box or circuit breaker.

2.Remove wall plate.

! Warning: Verify power is OFF to switch box before continuing.

3.Remove the switch mounting screws.

4.Carefully remove the switch from the switch box. DO NOT disconnect the wires.

5.There are five screw terminals on the 45609 switch; these are marked LINE (Hot), Neutral, LOAD, GROUND and TRAVELER. The Traveler terminal is only used for 3-way or 4-way wiring and should remain insulated if the 45609 is being installed in a 2-way system (one switch & one load). Match these screw terminals to the wires connected to the existing switch. (Do Not remove the tape over the terminal if you are not using the traveler connection).

6.Disconnect the wires from the existing switch.

7.Connect the green or bare copper ground wire to the GROUND terminal.

8.Connect the black wire that goes to the light to the terminal marked LOAD.

9.Connect the black wire that comes from the electrical service panel (Hot) to the terminal marked LINE.

10.Connect the white wire to the neutral terminal.

Note: UL specifies that the tightening torque for the screws is 14Kgf-cm.

7

Page 7
Image 7
Jasco 45609 manual Single, Dual and Triple, Gang Boxes, Warning - Shock Hazard