DPIP – Standard Input Module
See Figure 1
The standard DPIP input module features analog audio inputs and sophisticated onboard digital signal processing technology. Precision Bandpass limiting,
box.
CONTROLS
1)Subwoofer Filter Enable Select Switch
a)Momentary, Enables or disables the selected function. On subwoofer applications the
7)Input Sensitivity/Attenuation Control:
a)16 dB Precision Detented rotary control, 0.5 dB steps. Sensitivity +4 dBu nominal (+23 dBu clip) with the control fully counter clockwise, and
INDICATORS
2)Subwoofer Filter Enable
a)Orange LED, illuminates when the function is enabled.
�
�
�
�
�
�
�
�
3) FAULT | � |
a) Red LED, illuminates during any |
|
fault condition. |
|
4) THERMAL PROTECTION |
|
a) Orange LED, illuminates during |
|
thermal limiting: |
|
ai) PULSING indicates first stage of thermal
limiting, amplifier output level is reduced to prevent overheating.
aii) FLASHING indicates transducer thermal limits have been exceeded. Further reduction in output level is applied.
aiii) SOLID illumination indicates thermal protection is in the third stage of protection and amplifier shut down may occur if immediate
action is not taken to correct the external reason for excessive heating of the amplifier.
5)Ready
a)Green LED, illuminates when the system is ready for operation.
6)SIGNAL/CLIP
a)(Signal) Green LED, detects input signal above the threshold set at
c)(Clip) Red LED, Clip detection monitors input, DSP, and each amplifier output channel.The LED changes from Green to Red when clipping THD at any point is detected.
CONNECTORS
8)Audio In
a)
b)Pin 2 Hot (Positive voltage produces outward cone motion of L.F.Transducers).
9)Audio Out
a)
b)Pin 2 Hot (Positive voltage produces outward cone motion of L.F.Transducers).
JBL Professional 19