To Convert Appliance For Use With Natural Gas
If this appliance has been converted for use with LP gas, each of the following modifications must be performed to convert the unit back to natural gas.
A.Replace all orifice spuds
Perform Steps 1 through 4 on page 4.
For Step 5: Locate the colored brass natural gas orifice spuds that were originally installed in this appliance before its conversion for use with LP gas. Observe the color of each of the spuds and note the correct burner location for each spud as shown in figure 10.
Complete Steps 6 through 9 on page 5 to complete the installation of natural gas main spuds in their correct locations.
Save the orifices removed from the appliance for future use. They will be needed if this appliance is again converted for use with LP gas.
Installation of Natural Gas Orifice Spuds
Figure 10
B.Invert Appliance Pressure Regulator Cap
With the appliance installed, the regulator is located on the underside of the appliance at the inlet to the gas manifold. Identify the type of regulator on the unit and follow the instructions in the appropriate illustration. (See figures 7 and 8).
After Steps A and B have been completed, check the appearance of each burners’ flame at the Hi and Lo settings against figure 9. If the flames appear too large or too small, review all steps to make sure they were completed correctly.
Installation of Natural Gas Orifice Spuds
This appliance is equipped for electronic
This appliance has no air shutters, making adjustment of primary air unnecessary. The burners are designed to provide optimum aeration of all gases without air shutters. When operating properly, burners should produce clearly defined, even blue flames. If the flames have yellow tips or are hazy and otherwise appear to have insufficient air, obtain the services of a qualified service technician.
| NATURAL | PROPANE | ALL GASES |
| GAS | ||
| BURNER RATE | BURNER RATE | LO RATE |
BURNER | (BTU/HR) | (BTU/HR) | (BTU/HR) |
|
|
|
|
Right Front | 12,000 | 8000 | 1,600 |
Right Rear | 6,500 | 4500 | 800 |
Left Front | 6,500 | 4500 | 800 |
Left Rear | 10,500 | 8000 | 1,600 |
|
|
|
|
CAUTION: Never cover control knobs or surrounding control surface with utensils, towels or other objects. Never obstruct free air passage past the control knobs. The knob openings have been sized to properly control air entry to the interior of the appliance during operation.