JENN-AIR®DETAILED PLANNING DIMENSIONS

4 of 4

DOWNDRAFT SLIDE-IN RANGE DUCTING ARRANGEMENTS

DUCTING CONFIGURATIONS

5" (12.7 cm)

diameter duct

5" (12.7 cm) diameter

to 314" x 10"

(8.3 cm x 25.4 cm)

transition elbow

REAR DUCTING IN WALL TO ROOF

DUCTING REQUIREMENTS

range

duct length

duct size

 

 

 

 

10' (3.0 m) or less*

5" (12.7 cm)

 

diameter*

 

 

 

 

 

Dual Fuel,

 

6" (15.2 cm)

Gas

Between 10' (3.0 m)

diameter

 

and 60' (18.3 m)

314" x 10"

 

 

(8.3 cm x 25.4 cm)

 

 

 

 

10' (3.0 m) or less**

5" (12.7 cm)

 

diameter**

 

 

 

 

 

Electric

 

6" (15.2 cm)

Between 10' (3.0 m)

diameter

 

 

and 60' (18.3 m)

314" x 10"

 

 

(8.3 cm x 25.4 cm)

 

 

 

*Dual fuel ranges must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.

**May be used to vent straight out the back of the range and directly through the wall.

5" (12.7 cm)

diameter duct

5" (12.7 cm)

diameter wall cap

REAR DUCTING THROUGH WALL TO OUTSIDE

6" (15.2 cm)

diameter elbow

SIDE DUCTING IN TOE KICK TO OUTSIDE

CALCULATING MAXIMUM DUCTING LENGTH

Maximum ducting length is 60' (18.3 m).

Each 90° elbow equals 5' (1.5 m) duct.

Use no more than three 90° elbows.

Flexible metal vent is not recommended.

Do not install two elbows together.

NOTES:

For ducting runs up to 30' (9.1 m), install range as shipped.

For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the restricter ring on the blower inlet housing.

For altitudes above 4500' (1272.0 m), reduce recommended vent run by 20% for best performance.

5" (12.7 cm) to 6" (15.2 cm)

diameter

transition elbow

6" (15.2 cm)

diameter wall cap

THROUGH FLOOR between joists TO OUTSIDE

Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing

JRC120053 03/2012

any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.

Page 4
Image 4
Jenn-Air JES9800CA Downdraft SLIDE-IN Range Ducting Arrangements, Ducting Configurations, Ducting Requirements, 60 18.3 m