2 of 4 |
36" jx3™ Gas Downdraft Cooktop
JGD3536W – 36" x 183⁄8" x 211⁄2"
OPENING/CLEARANCE DIMENSIONS
A |
| E* |
|
|
|
|
|
|
| F |
B |
|
|
| B |
|
|
| G | H |
|
|
| I | |
|
|
|
| |
|
| v |
| e |
|
|
|
| |
| C |
|
| D |
|
|
|
| |
|
| v | J** |
|
|
|
| K | |
| C |
|
| |
|
|
|
|
FRONT VIEW
MODEL # | JGD3536W | |||
|
| in | cm | |
A | Width of combustible area above | 36 | 91.4 | |
cooking surface (min.) | ||||
|
|
| ||
B | Width from cooktop to fixed wall | 6 | 15.2 | |
or other combustible material (min.) | ||||
|
|
| ||
C | Width to center of vent opening option | 171⁄2 | 44.4 | |
D | Width to outer edge of outlet | 10 | 25.4 | |
E* | Height to bottom of uncovered wood or | 30 | 76.2 | |
metal cabinet above cooking surface (min.) | ||||
F | Height to bottom of uncovered wood | 18 | 45.7 | |
or metal cabinet (min.) | ||||
|
|
| ||
G | Height to center of vent opening option | 16 | 40.6 | |
H | Height to top edge of outlet (min.) | 12 | 30.5 | |
I | Height to top of gas installation area | 6 | 15.2 | |
J** | Depth to center of vent opening option | 171⁄8 | 43.5 | |
K | Depth of gas installation area | 6 | 15.2 | |
L | Depth of upper cabinet (recommended) | 13 | 33.0 | |
M | Depth from cutout to wall (min.) | 2 | 5.1 | |
N | Width of cutout | 343⁄4 | 88.3 | |
O | Depth of cutout | 20 | 50.6 | |
P | Depth from cutout to front of countertop | 21⁄8 | 5.4 | |
e | Recommended electrical access location |
|
| |
g | Recommended gas supply line location |
|
| |
v | Recommended venting location – |
|
| |
see pages |
|
| ||
|
|
|
*Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
**Based on installation in a 24" (61.0 cm) base cabinet.
Side
Cabinet
L
M
GAS REQUIREMENTS
Natural Gas
This cooktop is
LP Gas Conversion
Conversion must be done by a qualified service technician. To convert to LP gas, use the LP gas conversion kit provided with the cooktop.
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only,
VENTING REQUIREMENTS
This cooktop must be exhausted outdoors unless using the
LOCATION REQUIREMENTS
•To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout.
•A minimum clearance of 2" (5.1 cm) is recommended between the blower motor and cabinet for proper cooling. A 6" (15.2 cm) clearance is recommended for servicing access.
•An under counter
N M
O
P
Side VIEW | TOP VIEW – cutout |
|
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing | JRC120012A 07/2012 | |
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary. |