Jensen XA2150 Wiring, Power Terminal Batt +12V, Remote Terminal RMT +12V, Ground Terminal GND

Models: XA2150

1 12
Download 12 pages 9.84 Kb
Page 4
Image 4

®

XA2150

Wiring

Power and Outputs

FUSE

+ 12V

RMT

GND

30A

 

 

 

 

 

POWER

 

L +

L –

R –

R +

SPEAKER

Power Terminal (BATT +12V)

Connect directly to the vehicle battery+ terminal with 8 gauge wire (minimum).

+ 12V RMT GND

Remote Terminal (RMT +12V)

Connect the radio power antenna lead from the receiver to the amplifier REMOTE terminal. This turns the amplifier on whenever the re- ceiver is turned on. If a power antenna lead is not available, connect this wire to the radio or accessory fuse.

+ 12V RMT GND

Not Supplied

30 amp Fuse

or Circuit Breaker

Spade

Connector

8 Gauge

Spade

ButtConnector

Battery

Terminal

Adapter

Install as close

to the battery

as possible

To Battery+

Terminal

Wire

Connector

(not supplied)

8 Gauge

To Receiver

Power

Wire

Antenna Lead

Ground Terminal (GND)

Connect to a good chassis ground. The ground connection should be to clean, unpainted metal to provide a good electrical connection.

+ 12V RMT GND

 

 

Spade

 

Sheet Metal

Connector

Ring

Screw

 

(supplied)

 

Connector

 

 

 

 

 

8 Gauge

 

 

Wire

Drill 1/8" hole

 

 

in chassis

 

 

sheet metal

 

 

Fuses

FUSE

Use only one 30 amp blade-type fuse.

30A

4

Page 4
Image 4
Jensen XA2150 owner manual Wiring, Power Terminal Batt +12V, Remote Terminal RMT +12V, Ground Terminal GND, Fuses