John Lewis JLBIGGH605 instruction manual Engineer technical data, Supply Connections

Models: JLBIGGH605

1 24
Download 24 pages 6.19 Kb
Page 7
Image 7

Engineer technical data

OVERALL DIMENSIONS

Width:

590 mm

Depth:

520 mm

DIMENSIONS OF THE HOB CAVITY

Width:

560 mm

Depth:

480 mm

SUPPLY CONNECTIONS

Gas:

R 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230 V~ 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

APPLIANCE CLASS

 

3

APPLIANCE CATEGORY

II2H3+

GAS SUPPLY

G20 (2H) 20 mbar

HEATING ELEMENTS RATING

Rear Right Burner

1.9 kW

(semi rapid)

 

(6483 BTU/HR)

Front Right Burner

1.9 kW

(semi rapid)

 

(6483 BTU/HR)

Rear Left Burner

2.9 kW

(rapid)

 

(9895 BTU/HR)

Front Left Burner

1.0 kW

(auxiliary)

 

(3413 BTU/HR)

 

 

 

Burner

Dia. Tap

 

 

B y - p a s s

 

1/100 mm

 

Auxiliary 28

Semi-rapid 32

Rapid42

Aeration adjustment none

BURNER

RAPID

SEMI-RAPID AUXILIARY

TYPE OF GAS

 

 

 

 

 

 

 

 

 

 

POSITION

 

M A X

MIN

M A X

MIN

M A X

MIN

 

 

 

 

 

 

 

 

 

 

 

NOMINALTHERMAL

 

 

 

 

 

 

 

NATURAL GAS

POWER

kW

2.9

0.75

1.9

0.45

1.0

0.33

 

 

 

 

 

 

 

 

 

 

20 mbar

NOMINALFLOW

 

 

 

 

 

 

 

 

VALUE =

RATE

m3/h

0.276

0.062

0.181

0.043

0.095

0.031

 

37.78 MJ/m3

NOZZLEREFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

 

Ws - 50.7 MJ/ m3

 

 

1/100mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPG GAS

NOMINALTHERMAL

 

 

 

 

 

 

 

POWER

kW

2.7

0.75

1.9

0.45

1.0

0.33

 

28-30/37 mbar

NOMINALFLOW

 

 

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

 

 

RATE

g/h

196

46.8

138

32.4

73

23.8

 

49.92 MJ/Kg

 

 

NOZZLEREFERENCE

86

42

71

32

50

28

 

 

1/100mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7