John Lewis JLBIUCL 01 instruction manual Installation, Technical Data, Electrical connection

Models: JLBIUCL 01

1 20
Download 20 pages 49.03 Kb
Page 6
Image 6

Installation

It is dangerous to alter the specifications or attempt to modify this product in any way.

Care must be taken to ensure that the appliance does not stand on the electrical supply cable.

Technical Data

Dimensions of recess

 

Height

820 mm

Width

600 mm

Depth

550 mm

Dimensions of the appliance cavity

Height

815 mm

Width

596 mm

Depth

550 mm

Fridge Gross capacity

142 litres

Fridge Net capacity

140 litres

Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

WARNING:THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

If the plug that is fitted to your appliance is not suitable for your socket outlet, it must be cut off and the appropriate plug fitted.

Remove the fuse from the cut off plug.

The cut off plug should then be disposed of to prevent the hazard of shocks in case it should be plugged into a 13amp socket in another part of your home.

Important

The wires in the mains lead are coloured in accordance with the following code:

Green andYellow

- Earth

Blue- Neutral

Brown- Live

If you fit your own plug, the colours of the wires in the mains lead of your appliance may not correspond with the markings identifying the terminals in your plug, proceed as follows:

6

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

Heating elements rating

Supply voltage (50 Hz)

220-240 V

Connected load,

70 W

Fridge light

15 W

GREEN & YELLOW

13 AMP. FUSE

 

13 AMP

 

BROWN

 

BLUE

D207

CORD CLAMP

 

1.Connect the Green and Yellow (earth) wire to the terminal in the plug which is marked with the letter

«E» or the earth symbol or coloured green and yellow.

2.Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter «N» or coloured black.

3.Connect the brown (live) wire to the terminal in the plug which is marked with the letter «L» or coloured red.

4.Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.The plug moulded onto the lead incorporates a fuse. For replacement, use a 13amp BSI362 fuse. Only ASTA or BSI approved fuses should be used.

The plug must not be used if the fuse cover/carrier is lost.The cover/carrier is indicated by the coloured insert at the base of the plug.

A replacement cover/carrier must be obtained from your local Service Force Centre.