Humidifier Specifications
|
| A. Unit Size |
|
|
|
|
| ||
|
|
| (inches) |
|
|
|
|
| |
| Sizing | B. Plenum | Bypass |
|
|
|
| ||
Humidifier | Sq. Ft. Area |
| Opening | Connection | Water Feed | Electrical | UL | Components | |
Type | (air changes/hr) |
| (inches) | Size | Rate | Data | Approved | Included | |
|
|
|
|
|
|
|
|
| |
| 120V operation: |
|
|
|
|
| Manual Humidistat, | ||
| 750 loose (2), 1,500 average |
|
|
|
| 11.5 AMP, |
| ||
| A. | N/A – |
|
| Dispersion Tube, | ||||
| (1), 3,000 tight (1/2) | N/A – Total | 1.4 kW |
| |||||
8000 Series | 208V operation: |
| Dispersion | water usage | UL | Steam Hose, Drain | |||
| tube mounts | Hose, Hose Clamps, | |||||||
Canister |
| is output plus | Approval | ||||||
1,350 loose (2), 2,650 average |
|
| through | 11.5 AMP, | Blower Activation | ||||
Steam | B. N/A – Unit | approximately | certified | ||||||
(1), 5,350 tight (1/2) | 2.4 kW | Relay, Installation/ | |||||||
Humidifier | 20% for drain | by ETL | |||||||
|
| can be remote | in supply or |
| Operation & | ||||
| 240V operation: |
| cycles. |
| |||||
|
| mounted. | return duct. |
| Maintenance Manual, | ||||
| 1,500 loose (2), 3,050 average |
|
| 11.5 AMP, |
| ||||
|
|
|
|
|
| Owners Manual | |||
| (1), 6,100 tight (1/2) |
|
|
|
| 2.8 kW |
| ||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
| 1,050 loose house (2) | A. |
|
|
|
| Manual Humidistat | ||
7000 Series |
| 18 H x |
|
|
|
| |||
|
|
|
|
| Saddle Valve, | ||||
Power | 2,100 average house (1) |
| N/A | 6 gph | Yes | ||||
|
| 0.8 AMP | Installation Template, | ||||||
Humidifier |
| B. |
|
|
| ||||
4,200 tight house (1/2) |
|
|
|
| Owner’s Manual | ||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
| A. |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
| 1,000 loose house (2) |
|
|
|
|
| Manual Humidistat | ||
6000 Series |
| 6” dia. round |
|
|
|
| |||
|
|
|
|
| Saddle Valve, | ||||
|
|
|
|
| |||||
Bypass | 2,000 average house (1) |
| opening | 6” | 3 gph | Yes | Installation Template, | ||
| 0.5 AMP | ||||||||
Humidifiers |
|
| for bypass |
|
|
| Owner’s Manual, | ||
4,000 tight house (1/2) |
|
|
|
|
| ||||
|
| connection |
|
|
|
| |||
|
|
|
|
|
|
| |||
|
| B. | 10 W x |
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
| A. |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
| 1,000 loose house (2) |
|
|
|
|
| Manual Humidistat | ||
4000 Series |
| 6” dia. round |
|
|
|
| |||
|
|
|
|
| Saddle Valve, | ||||
Water Saver |
|
|
|
|
| ||||
2,000 average house (1) |
| opening | 6” | 3 gph | No | Installation Template, | |||
Bypass |
| 0.5 AMP | |||||||
|
| for bypass |
|
|
| Owner’s Manual, | |||
Humidifiers | 4,000 tight house (1/2) |
|
|
|
|
| |||
| connection |
|
|
|
| ||||
|
|
|
|
|
|
| |||
|
| B. | 10 W x |
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
| A. |
|
|
|
|
| ||
|
|
| 13 H x |
|
|
|
|
| |
| 750 loose house (2) |
|
|
|
|
| Manual Humidistat | ||
5000 Series |
| 6” dia. round |
|
|
|
| |||
|
|
|
|
| Saddle Valve, | ||||
|
|
|
|
| |||||
Bypass | 1,500 average house (1) |
| opening | 6” | 3 gph | Yes | Installation Template, | ||
| 0.5 AMP | ||||||||
Humidifiers |
|
| for bypass |
|
|
| Owner’s Manual, | ||
3,000 tight house (1/2) |
|
|
|
|
| ||||
|
| connection |
|
|
|
| |||
|
|
|
|
|
|
| |||
|
| B. |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
Series 8000, 7000, 6000, 5000, 4000 humidifier performance based on:
a.20°F and 70% R.H. Outside Air
b.0°F and 35% R.H. Room Air
c.Internal Moisture Gain of 1 lb/hr
d.70% Blower Operation
e.8 Ft. Ceiling Height
Johnson Controls
Unitary Products
5005 York Drive, Norman, OK 73069
Johnson Controls, Unitary Products reserves the right to change specifications without notice.