INTRODUCTION

INTRODUCTION

Thank you for your recent steam humidifier purchase.. We appreciate your business and are pleased to add your name to our growing list of customers.. You have invested in the highest quality equipment available..

Your humidifier will require periodic maintenance to assure continued consistent performance.. See page 10..

Please take a few minutes and read this booklet.. This will familiarize you with the benefits you will receive from the humidifier and help you understand the routine maintenance that will be required..

Replacement Model S1-8044 Steam Canisters are available from your installing contractor or from most other heating and air conditioning contractors in your area. Look in the Yellow Pages under Humidifying Apparatus or Heating & Air Conditioning Contractors.

PRINCIPLES OF OPERATION

The Steam Humidifier delivers humidity in the form of steam to the conditioned space via the HVAC system duct or optional Model S1-854Y Fan Pack.. The humidifier generates steam by energizing two electrodes that extend into a canister of water.. Current flowing between the electrodes causes the water to boil, creating steam.. Water is introduced to the humidifier through a fill valve to a fill cup located in the top of the cabinet.. The fill cup serves as an overflow reservoir and provides an air gap between the humidifier and water source.. The steam canister is filled from the bottom.. The canister is seated in a drain cup assembly which includes a drain valve.. The drain and fill valves work together to maintain water level in the canister to deliver the rated steam capacity based on the electrical conductivity of the water and to temper drain water.. See Figure 1 for representation of fill and drain system and canister..

Steam is delivered into the airstream through a dispersion tube mounted in the HVAC system ductwork.. Openings in the dispersion tube are fitted with “tubelets” which extend into the center of the tube.. The design of the dispersion tube and tubelets distribute steam over a wide area in the duct and direct any condensed moisture back into the steam hose..

- 4 -

Figure 1 – Fill and Drain System and Canister

 

 

Steam

 

 

Outlet

 

Fill Cup

 

 

 

Overflow

 

 

 

High Water

 

 

Level Sensor

 

 

Electrodes

Flow Control

 

 

Orifice

 

 

 

 

Canister

Inlet

Fill

 

 

 

Fill Valve

 

Drain Valve

 

 

Drain Cup

 

Supply

 

 

Water

 

 

Drain

 

 

 

90-1522

SEQUENCE OF OPERATION

When the Humidifier Control detects humidity below the set point, and provided the humidifier is turned on and the indoor unit blower is operating, the internal controller in the humidifier energizes the electrodes and measures the current flowing through the water between them.. The controller adjusts water level in the canister via a fill valve and a drain valve to maintain a constant current.. The operating water level in the canister depends on the mineral content of the water which determines conductivity..

A relay is provided with the humidifier that will allow the control to turn on the indoor unit blower when a call is made for humidity..

- 5 -