OUTDOOR UNIT MODIFICATIONS

OUTDOOR UNIT MODIFICATIONS

1.Disconnect all high and 24V voltage power to the unit and the control circuit.

2.Mark and disconnect all thermostat, sensor and low volt- age control connections from the YorkGuard IV control.

3.Remove the six #10 screws holding the control and remove the control.

4.Using five of the six screws removed in Step 3, mount the new board in place (omit the top middle screw).

5.Reconnect the wires removed in Step 2.

INDOOR UNIT MODIFICATIONS

NOTE: Indoor transformer should be rated for a minimum of 40VA. Replace transformer if necessary.

FOSSIL FUEL APPLICATION - The YorkGuard VI control does not require an add-on fossil fuel kit. Remove existing fossil fuel kit if present. An optional bonnet sensor may be used if desired. See “OPERATION INSTRUCTIONS - “DEMAND DEFROST CONTROL BOARD” on upgnet.com for details of functionality with and without bonnet sensor installed.

START-UP OPERATION

1.Reapply power to the unit and the control voltage circuit.

2.The LED on the defrost control will flash on and off when there is power to the control and it is working properly.

3.Verify unit operation.

For more information on control operation, refer to “OPER-

ATION INSTRUCTIONS - “DEMAND DEFROST CONTROL BOARD” on upgnet.com.

Subject to change without notice. Published in U.S.A.

035-22286-001-A-0909

Copyright © 2009 by Johnson Controls, Inc. All rights reserved.

Supersedes:Nothing

Johnson Controls Unitary Products

5005 York Drive

Norman, OK 73069

Page 2
Image 2
Johnson Controls yzh, yzb, yze, hl8, hl5 Outdoor Unit Modifications, Indoor Unit Modifications, Start-Upoperation, Norman, OK

FAQ

How do I modify the outdoor unit?

Disconnect power, disconnect control connections, remove control, mount new board, and reconnect wires.

What should I do for indoor unit modifications?

Ensure the transformer is rated for a minimum of 40VA, remove fossil fuel kit if present, and use an optional bonnet sensor if desired.

What should I do for start-up operation?

Reapply power, verify unit operation, and refer to control operation instructions for more information.