GF 400 BV SebagoSpecifications

The Jøtul GF400 BV Sebago is a atmospherically-

vented gas fireplace heater designed only for

vertical venting directly to the outside of the house,

using listed, Type B-vent pipe.

Input Rates

Natural Gas

40,000 BTU/hr. maximum input
22,000 BTU/hr. minimum input

Propane

40,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane: 12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 1.2 WC (.30 kPa) 3.8 WC (.95 kPa)
Propane: 2.9 WC (.722 kPa) 11.0 WC (2.74 kPa)
Piezo Ignitor / Standing Pilot

Suggested Tools for

Installation and Service

External regulator (for Propane only)
Piping which complies with local code
Manual shutoff valve (T-Handle in Massachusetts)
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench or deep socket
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
4 mm allen wrench
• Gloves
Safety glasses
Torx T20 screwdriver
Leak test solution
Reciprocating Saw
Power Drill
THIS FIREPLACE IS SHIPPED FROM THE FACTORY
FOR USE WITH NATURAL GAS ONLY. FOR USE WITH
PROPANE, THE APPLIANCE MUST FIRST BE
CONVERTED USING #156003 FUEL CONVERSION KIT
PROVIDED. CONVERSION SHOULD BE MADE
BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 11.
With Short Legs, reduce height by 2 1/4” ( 51 mm)