GAS CONVERSION:
The Allagash B-Vent gas stove is shipped from
the factory equipped as a NATURAL GAS unit;
However, the stove is shipped with the necessary
gas conversion kit to convert the stove to burn
PROPANE GAS. These kits contain all the
necessary components needed to complete the
task and ensure safe operation, including labeling
that must be affixed to the stove.
WARNING:
THE CONVERSION KIT IS TO BE INSTALLED BY
AN AUTHORIZED JØTUL SERVICE TECHNICIAN
IN ACCORDANCE WITH THE
MANUFACTURERS INSTRUCTION AND ALL
CODES AND REQUIREMENTS OF THE
AUTHORITY HAVING JURISDICTION. FAILURE
TO FOLLOW THESE INSTRUCTIONS COULD
RESULT IN SERIOUS INJURY OR PROPERTY
DAMAGE. THE QUALIFIED AGENCY
PERFORMING THIS WORK ASSUMES
RESPONSIBILTY FOR THIS CONVERSION.
IN CANADA:
THE CONVERSION SHALL BE CARRIED OUT IN
ACCORDANCE WITH THE REQUIREMENTS OF
THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN1-B149.1 AND
.2 INSTALLATION CODE.
Cet equipement de conversion sera installe par
une agence qualifiee de service conformement aux
instructions du fabricant et toutes exigences et
codes applicables de lautorises avoir la
juridiction. Si linformation dans cette Instruction
nest pas suivie exactement, un fey, explosion ou
production de protoxyde de carbone peut resulter
blessure personnelle de vie. Lagence qualifiee
de service est esponsable de linstallation nest
pas propre et complete jusqua loperation de
lappareil converti est cheque suivant les criteres
etablis dans les instructions de proprietaire
provisionnees avec lequipement.
Tools required:
1/4 Nut driver, 7/16 and 1/2 open end
wrench or deep well socket, 4mm allen
wrench, Torx t20 or slotted screwdriver.
Included in the conversion kit:
1 regulator tower labeled for propane
3 regulator tower screws
1 burner orifice (#54 LPG)
1 pilot orifice ( #30 for LPG, #51 for NG)
Label A - to be completed and adhered to the
back of the stove.
Label B - to adhere to the stoves rating plate.
IMPORTANT:
If the forced air blower kit is installed, be sure
to unplug blower before proceeding with this
conversion. Any gas supply must be turned
off and disconnected from the valve.
Conversion instructions are also shipped in the
stove with the conversion kit.
Gas Conversion Procedure
1. Turn off gas supply to the stove.
2. Lift off top plate (5).
3. Release the glass clips atop the stove and
slowly lift glass panel (10) up and out of track.
4. Remove the log set (12) using care not to
scratch or damage logs.
5. Lift out the log support (14). Remove the air
divider (15) by lifting the right side and slowly
rotating forward.
6. Remove burner tube (13): Using a ¼ nut
driver remove the two screws securing the
burner tube (13) to the stove bottom. Lift out
the burner tube.
7. Change the main burner orifice. Using a ½
open end wrench or deep well socket remove
the burner orifice and replace with the
appropriate orifice, supplied in the kit.
10