Connection/Installation (VN-V685U/VN-V686BU)

Mounting the Camera

Preparation

Be sure to put on protective glasses to protect your eyes from falling objects when mounting the camera.

1Make holes on the ceiling

Use the provided template to make a hole (R80 mm) for the connection cables to thread behind the ceiling.

If necessary, also open a screw hole to mount the ceiling clamping bracket to the ceiling. In this case, align the AD FRONT markB of the template in the direction where the camera faces front and open the screw hole.

2Pull the cables from the hole in the ceiling

Pull out the fall prevention wire, power cable, coaxial cable, control signal cable, alarm signal cable and provided alarm cable that were mounted to the ceiling slab from the ceiling.

1

80

 

Fall

LAN Cable

Preventio

 

 

Power cable

Alarm signal

2

cable

 

Note:

Mount the fall prevention wire on a firm place with sufficient strength.

3Remove the ceiling clamping bracket from the camera unit

The ceiling clamping bracket is attached to the camera unit during packaging of the product. Before installing the camera, remove the ceiling clamping bracket from the camera unit.

ACheck to make sure that the two camera lock knobs (left and right) are unlocked.

If they are locked, unlock by sliding them in the direction indicated by the arrow.

BPress the two camera lock knobs from both the left and right sides in the direction indicated by the arrows.

Doing so detaches the ceiling clamping bracket from the camera. Prevent the bracket from dropping such as by performing this on a table.

Memo:

If the camera fixing lock knob is too stiff, push the knob hard while pressing the edge of the camera unit (A in the diagram) against the table you are using.

CLifting the camera unit detaches the ceiling clamping bracket. Remove by sliding it in the direction indicated by the arrows.

A

A

Camera fixing lock knob (x2)

B

BC

Ceiling mount

Camera

4Remove the terminal cover

Loosen two screws on the ceiling clamping bracket and remove the terminal cover.

Terminal cover

5Mount the fall prevention wire that connects the ceiling clamping bracket to the ceiling

 Fall Prevention Wire

6 mm

6 mm (3/16

R6 mm and

R4 to 5.5 mm

18