Setting (continued)
B 1st Trigger | This item specifies the first trigger to the operation set in [Action] A. |
| |||
| [Setting value:Input 1 Make, Input 2 Make, Input 1 Break, Input 2 Break, |
| |||
| Motion Detection, Fan Stop, Position, BlackWhite → Color, Color → |
| |||
| BlackWhite] |
|
| ||
| Memo: |
|
|
| |
|
|
|
| ||
|
| ● When the second trigger is turned off, the action will be invoked only by |
| ||
|
| the first trigger. |
|
| |
|
| ● When AMotion DetectionB, AFan StopB, APositionB, ABlackWhite→ColorB, |
| ||
|
| AColor → BlackWhiteB is selected as the first trigger, selection of AMax. |
| ||
|
| IntervalB and A2nd TriggerB will be disabled. |
| ||
|
|
|
| ||
|
|
| |||
C Max. Interval | Enabled when both the first and second triggers are specified. |
| |||
| Specify the maximum interval between the first and second triggers. An |
| |||
| action will be invoked only if the interval between the first and second |
| |||
| triggers is within the maximum interval. |
| |||
| [Setting range:1sec to 3600sec] |
| |||
|
|
| |||
D 2nd Trigger | This item specifies the second trigger to the operation set in [Action] A. |
| |||
| [Setting value:Off, Input 1 Make, Input 2 Make, Input 1 Break, |
| |||
| Input 2 Break] |
|
| ||
|
|
| |||
E Action Position | This item sets the position number for trigger when APositionB is selected in |
| |||
No. | [Action] A. |
|
| ||
| [Setting range:0 to 99] |
| |||
|
|
| |||
F Trigger Position | This item sets the position number for trigger when APositionB is selected in |
| |||
No. | [1st Trigger] B. |
|
| ||
| [Setting range:0 to 99] |
| |||
|
|
|
| ||
G Mail | Mail Address | : For entering the recipient’s mail address. |
| ||
| Mail Text | : For entering the mail transmission data. Input up to 127 |
| ||
|
|
|
| alphanumeric characters. |
|
| Attach Image | : For specifying whether to attach images to the mail. |
| ||
|
|
|
|
|
|