Introduction

Names of Parts (continued)

Rear panel

RM-HP790DU

TALLY

 

INTERCOM

 

AUX VIDEO INPUT

GENLOCK INPUT

 

VIDEO OUTPUT

INPUT

OUTPUT

 

PGM PVW C

H

C

G

Y/G

PB/B

PR/R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HD/SD SDI

REMOTE

 

 

 

 

 

 

 

 

 

 

 

AC H IN AC120V 60Hz

 

 

 

RTS

 

 

 

COMPOSITE VIDEO

 

 

CAMERA CABLE

 

 

 

 

 

 

 

 

 

 

A B C D E F G H I J

RM-HP790DE

TALLY

 

INTERCOM

 

AUX VIDEO INPUT

GENLOCK INPUT

 

VIDEO OUTPUT

INPUT

OUTPUT

 

PGM PVW C

H

C

G

Y/G

PB/B

PR/R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HD/SD SDI

REMOTE

 

 

 

 

 

 

 

 

 

 

 

AC H IN 230V H 50Hz

 

 

 

 

 

 

 

COMPOSITE VIDEO

 

 

CAMERA CABLE

 

 

 

 

 

 

 

 

 

 

A B C D E F G H I J

A[ACHIN] Connector

Connect this socket to a commercial power supply outlet using the power cord provided.

B[TALLY] Terminals

These terminals input the tally control signals. (A Page 14 [Tally])

C[INTERCOM] Terminals

These terminals input and output the intercom signals. In a system composed of multiple cameras and remote control units, the intercom function provides intercommunication between operators.

(A Page 14 [Intercom])

D[AUX VIDEO INPUT] Connectors

These connectors are used to input the return video signal, which returns the SEG (Special Effects Generator) or switcher output signal to the camera viewfinder.

These two connectors are loop-through connected inside to enable a bridge connection.

They are terminated automatically when they are not bridge- connected. Input VBS.

E[GENLOCK INPUT] Synchronous Signal Input Connectors

These connectors are for reference sync signal input. These two connectors are loop-through connected inside to enable a bridge connection.

They are terminated automatically when they are not bridge- connected.

Input BB or Tri-level sync signal.

F[Y/G, PB/B, PR/R] Component Video Signal Output Connectors

The settings of the output signals from these connectors can be switched between Y/PB/PR, G/B/R using the Signal Serect switch on the connected camera or by using the menu setup of the camera.

G[COMPOSITE VIDEO] Signal Output Connector

This connector outputs VBS (composite video) signal.

H[HD/SD SDI INPUT/OUTPUT] SDI signal input and output connectors

These are HD/SD SDI signal input/output connectors. SDI signal that is input will be output from the [HD/SD SDI OUTPUT] connectors.

Memo :

Transferred signals cannot be output via the camera cable from the [HD/SD SDI OUTPUT] connector on RM-HP790DU/RM-HP790DE. Signals will be output in the same format as the input signals to [HD/SD SDI INTPUT] connector.

I[REMOTE] Connection Connector of Remote Control Panel

This connector connects to the remote control panel and controls the camera.

When connected, remote control panel operations will take priority over operations from RM-HP790DU/RM-HP790DE (3: FILE, 4: PROCESS, 5: OPERATION).

6