Installation

Mounting the Camera Using the Conduit Hole at the Side of the Base

If the camera cannot be mounted directly to the ceiling, use the conduit hole at the side of the base to mount the camera to the pipe.

Conduit hole: G3/4-14 UNC (TK-C2201WPU), M25 (TK-C2201WPE)

1Remove the dome cover and inner dome (A page 13)

2Remove the camera unit from the base and mount the fall

prevention wire to the camera unit

Refer to "Mounting the Camera Using the Conduit Hole at the Bottom of the Base" (A page 19) step 2.

3Wind the sealing tape

Wind the sealing tape around the pipe junction (where the conduit hole thread lines with the pipe screw hole) two or more times.

4Remove the conduit plug from the base

Loosen the mounting screw (M3 x 6 mm) using a flathead screwdriver and remove the conduit plug at the side of the base.

5Mount the conduit plug that was removed to the conduit hole at the bottom of the base

6Mount the base to the pipe

Screw the pipe to the conduit hole at the side of the base.

Note When screwing the pipe, do not screw beyond 12 mm. Doing so can damage the camera interior.

Conduit plug

4

Mounting screw

.

3

Sealing tape

6

5