Installation
Mounting the Camera (Continued)
3Wind the sealing tape
Wind the sealing tape around the pipe junction (where the conduit hole thread lines with the pipe screw hole) two or more times.
4Mount the base to the pipe
Turn and screw the base unit to the pipe in the clockwise direction.
Note When screwing the pipe, do not screw beyond 12 mm. Doing so can damage the camera interior.
5Secure the base unit to the ceiling
Use the M4 screw (x2) to secure the base firmly to the ceiling.
Note v Make sure there is no gap between the ceiling and the base.
vThe M4 screws are not provided. Use a suitable type of screws according to the material of the mounting location.
6Mount the fall prevention wire to a structurally strong location
3
Sealing tape
12 mm and below
6
4
Fall prevention wire 8mm
2mm
5
M4 mm screw
.
7Connect the cables (A page 15)
Push the connector of the connected coaxial cable back to the pipe.
8Mount the camera unit to the base
①Push in until the catch (2 locations) snaps on.
Note Make sure that the cables and the fall prevention cable are not caught between the camera and the base during mounting.
②Fasten the camera unit fastening screw (2 locations) to secure the camera.
9The procedures for the following are the same as that for normal camera mounting