Mounting the Camera (VN-C625U)

1.

Screw (M4) x 4

2.

Screw (M3) x 2

 

Converter Unit

Mounting Bracket

Camera

Mounting 4.

Bracket

Connector

Main Housing Unit

3.

Connector

To [POWER INPUT DC 12 V]

Terminal of Ceiling Mount

Connect to AC 24 V Output Cable

Preparation

1. Dismantle the camera mounting bracket

Loosen the screws on the camera mounting bracket (M4, 4 pcs) using a driver to dismantle it.

2. Dismantle the converter unit mounting bracket

Loosen the screws on the converter unit mounting bracket (M3, 2 pcs) using a driver to dismantle it.

3. Mount the converter unit to the housing

Clamp the converter unit using the converter unit mounting bracket, followed by mounting it to the housing using the screws (M3, 2 pcs) removed in Step 2.

When mounting, pay attention to the orientation of the converter unit as shown in the left diagram.

4. Mount the camera mounting bracket

Mount the camera mounting bracket dismantled in step 1. to the housing. Mount it exactly to the original position.

Mounting

Before mounting.

Remove the ceiling mount cover of the camera and guide the cables supplied with WB-1540U through the cover.

TFor further details, please refer to the instruction manual of the camera in use.

1. Connect the AC 24 V output cable to the converter unit.

Follow the procedures below to connect the AC 24 V output cable of the main board on the main housing unit to the converter unit.

Press

AC 24 V Output Cable

A Push both ends of the connector as shown in the left diagram to remove it from the supplied converter unit.

5mm

Press

1.

Press

Connector

 

 

 

Main Board

 

 

 

AC 24 V

 

 

To [POWER

Output Cable

 

 

 

 

2. INPUT DC

 

 

 

5mm

 

 

12 V]

 

 

Terminal of

Connector

 

 

 

 

Ceiling

 

Interior of Housing

Mount

 

 

 

 

JVC Mark

Notch

 

 

 

Main Board

Safety Wire

Camera Mounting Bracket

 

Cables

Cover

 

3.

FRONT Mark

 

4.

Ceiling Mount

 

 

Screws Supplied (M4 x 20) x 4

5.

Camera

B Cut the Y terminal of the AC 24 V output cable and peel off about 5 mm of the coating.

C Push the arrow mark using tools such as a flat-head screwdriver to insert the coating of the AC 24 V output cable into the connector.

D Attach the connector to the converter unit.

2. Mount the Y terminal of the converter unit to the ceiling mount of VN-C625U.

Guide the Y terminal of the converter unit through the ceiling mount cover, followed by connecting it to the [POWER INPUT DC 12 V] terminal of VN-C625U’s ceiling mount.

3. Connect other cables

Connect the necessary cables supplied with the housing (coaxial video cable, alarm signal cable, LAN cable, etc.) to the corresponding terminals on the ceiling mount.

CAUTION:

Connect the communication cable to the alarm terminal if necessary. In addition, DC 12 V Power Cable is not in use on this system. For safety reasons, ensure to cut off any excess cable and bind using an insulating tape before use.

For further details on connection, please refer to the instruction manual of the camera in use.

4. Mount the camera’s ceiling mount to the main housing unit.

Use the 4 screws supplied (M4 x 20) to mount the ceiling mount to the main housing unit.

NOTE:

During mounting, align the [D FRONT] mark of the ceiling mount with the notch on the camera mount bracket of the main housing unit.

5. Mount the camera to the ceiling mount

Follow instructions in the manual of the camera in use to mount the camera to the ceiling mount.

7

Page 7
Image 7
JVC WB-1550U, WB-1540U manual Mounting the Camera VN-C625U