Kambrook KBV40 manual Using Your Kambrook Jaguar Vacuum Cleaner, Variable Power Control

Models: KBV40

1 4
Download 4 pages 48.55 Kb
Page 3
Image 3

Using Your Kambrook Jaguar Vacuum Cleaner

Remove all packaging from the unit, hose and other accessories; ensure that you have removed all of the accessories before discarding the packaging.

Ensure that the dust canister and filters are correctly fitted.

Locate the crush proof hose and push the connection point into the hose inlet connection on the front of the unit, until a “click” sound is heard.

Connect the wide end of the metal wand to the hose end, and push together firmly.

Fit the floor tool to the narrow end of the wand/s and push together firmly.

Fully extend the power cord by pulling the power plug (situated at the rear of the unit) out from the unit, until the yellow tape on the cord is shown.

ENSURE THAT YOU DO NOT OVER EXTEND THE POWER CORD

DO NOT EXTEND PAST THE RED WARNING TAPE ON THE CORD

Plug into a 230/240v power point and switch the power on.

To commence vacuuming push down on the on/off foot pedal, at the top, rear of the unit.

When vacuuming is complete, push down on the ‘on/off’ pedal to switch off. Using Your Kambrook Jaguar Vacuum Cleaner Turn the power off at the outlet and then remove the power cord from the power outlet (when removing plug from the power outlet grasp the plug not the cord).

To retract the cord push down on the ‘cord rewind’ pedal.ENSURE THAT YOU DO NOT OVER EXTEND THE POWER CORD

IMPORTANT: HOLD THE PLUG END WHEN RETRACTING THE CORD TO PREVENT IT FROM STRIKING YOU OR THE VACUUM.

Variable Power Control ALWAYS ENSURE THAT THE DUST CANISTER AND THE MOTOR PROTECTION FILTER ARE CORRECTLY FITTED. NEVER OPERATE WITHOUT THE DUST CANISTER AND FILTERS IN PLACE.

Variable Power Control

The On/off button, on the top of the unit, is also to be used for variable power control. Turn the control clockwise for maximum power for vacuuming hard floor and carpet surfaces.Turn the control anti- clockwise for minimum power when using the crevice and brush tools.

Crevice and brush tool accessories

The crevice tool is ideal for vacuuming hard to reach places such as the edges along skirting boards.

The brush tools can be used to vacuum delicate surfaces and areas such as shelves and venetian blinds.

Set the variable speed control between minimum and medium power when using the tool accessories.

Turn off the vacuum cleaner when changing any attachments.

Dust canister indicator and dispensing the dust canister

The dust canister should be emptied when full.The dust canister indicator window will gradually turn red as the

canister fills up.When the dust canister indicator displays ‘red’ it is time to empty the canister. Otherwise you can look

at the canister at the back end of the unit and decide when you would like to empty it.

Always switch appliance off, then switch off at the power outlet and unplug the appliance prior to replacing filters or emptying the dust canister.

To remove the dust canister, ensure the unit is down on its wheels; Remove the dust canister by clasping the handle and pressing down on the button above the dust canister. Once released slowly pull the canister toward you.

To empty the dust canister simply place it above the rubbish bin; lift the “lift and press” lever and then press the button. The bottom of the canister will release and the dust and compiled dirt will be dispensed.

IMPORTANT: DO NOT USE THE UNIT WITHOUT A DUST CANISTER IN PLACE

Cleaning and replacing filters

Filters must be cleaned from time to time to remove the fine dust particles that have been collected.

1.Remove the dust canister from the unit

2.Lift the lid of the dust canister

3.Take off the mesh filter by lifting it vertically; this filter can be washed in luke warm water. Ensure you let the filter completely dry naturally before next use.

4.To remove the HEPA filter rotate the filter in an anti-clockwise position until released.Then lift the HEPA filter vertically to remove.

5.Tap and shake the filter until all the fine dust particles are removed. However after approximately 6 months the filter should be replaced.

6.To place the filter back in the dust canister simply place the HEPA filter in the dust canister lid and turn the filter in a clockwise direction to lock it

in place.

7.To place the mesh filter bracket back in place, ensure that it is completely dry before use. Simply place the filter on top of the HEPA filter and ensure the indents in the mesh filter holder meet with the grooves in the dust canister lid.This will ensure that the mesh filter bracket is locked in place.

8.Place the complete filter assembly back on top of the dust canister. Place the dust canister back in the vacuum cleaner for next use.

Motor protection filter

The motor protection filter must always be in place when operating the vacuum otherwise damage to the motor may occur.

To replace the motor protection filter – remove the dust canister.The motor protection filter is located at the rear of the inner chamber. Pull the plastic filter holder toward you to remove. Replace the filter and push the holder back in place once filter replacement been made.

4

5

Page 3
Image 3
Kambrook KBV40 manual Using Your Kambrook Jaguar Vacuum Cleaner, Ensure That You Do Not Over Extend The Power Cord