3.2.3Bleeding the Metering Pump

WTC 600 LP / MP

Version 06/05

Maintenance and Care

 

 

 

After a while the indication moves back to the current time.

• Screw in the bleeding screw again.

31

32

3.2.3Bleeding the Metering Pump

production / production produccion / produzione

fault / default error / guasto

disinfection / nettoyage desinfeccion / disinfezione

reject / rejet

evacuation / evacuatione

regeneration / regeneration regeneracion / rigenerazione

tank full / stockage plein deposito lleno / serbatoto pieno

RO 1000

36

ESC

The metering pump must be bled when the pump has drawn in air (e. g., because the metering con- tainer is completely empty).

• The system stops; the “Motor/hard water“ mal-

function indication is shown in the display.

i

This malfunction indication is shown in-

dependent of which metering container

is empty.

• Fill the empty metering container and mix the

On the control panel, acknowledge the mal- function indication with the RETURN key but- ton (36); the system starts.

3.2.4Replacing the Fine Filter

Check the pressure difference at manometers (15) and (16). Replace the filter insert when over 0.8 bar:

Switch off the equipment at the main switch (20).

Stop the untreated water supply.

chemicals according to Section 3.2.6.

3.2.4Replacing the Fine Filter 33

34

35

16

15  33 37

38

39

40

41

Unscrew the bleeding screw (34) by one turn.

Press the MANUAL pushbutton (33) until the medium flows without bubbles through the bleeding line (35) back into the container.

Place a bucket under the untreated water drain cock (37) and open the cock.

Wait until no more water emerges out of the cock, then shut the cock again.

Attach the filter wrench (41) to the filter bowl (40) and screw off the filter bowl.

i

The filter bowl is still filled with water.

 

Remove the filter insert (38) from the filter bowl and replace with a new one.