Operating Instructions HD 10/25 S USA | English |
|
|
Preparing the unit for use
Unpack the unit
–When unpacking the unit, check the con- tents of the packaging. If there has been any damage in transit inform the dealer.
–Do not dispose of the packaging with the household rubbish, hand it in at the appro- priate collection point for recycling.
Check the oil level
Read the oil level displayed while unit is at a standstill. The oil level must be above the two indicators.
Activate the oil reservoir vent
Unscrew the fastening screw of the hood and remove the hood.
Cut off the tip on the cover to the oil reser- voir.
Fasten the unit cover.
Mount the accessories
Mount nozzle on the spray lance (see markings on the top of the setting ring).
Fit the spray lance to the
Lock cable clincher into bore lateral to the handle.
Tighten the
Switching on the unit
Electrical connection
Caution!
The voltage specified on the model rat- ing plate must correspond to the voltage sup- plied.
Caution!
The maximum tolerable mains impedance at the electrical contact point (see Technical Data) must not be exceeded.
Caution!
Use an extension cable with a sufficient cable
For connected loads see model rating plate/ Technical Specifications.
Caution!
It is essential that the unit is connected to the power supply by means of a plug. An in- separable connection to the power supply is prohibited. The plug is used to disconnect from the mains.
Water connection/Suction feed operation
Connection to water main
Caution!
Pay attention to the regulations of the water supply company; according to DIN 1988, the unit may not be connected direct to the public drinking water supply. A
(Order no.
For connected loads see Technical Specifica- tions.
Connect a supply hose (not supplied) to the water outlet on the unit and to the water in- let (e.g. water tap).
Open water inlet.
8