Karcher HDS 1195, HDS 1295, HDS 745 Once a month, Display, Clean strainer in low water protection

Models: HDS 995 HDS 1195 HDS 745 HDS 695 S HDS 895 S HDS 1295

1 17
Download 17 pages 9.93 Kb
Page 10
Image 10
Once a month

English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295

10

Once a month

Display

 

Clean strainer in low water protection

Clean filter at cleaning-agent suction hose

 

 

 

 

 

Necessary maintenance work

 

After 500 hours of operation, at least once a

 

Check the overflow valve for leaks *

 

year

 

Check the high-pressure hose *

 

Change oil

 

Clean the handgun

 

 

 

 

 

Check the pulsation damper *

 

 

 

 

 

* This maintenance work should be performed

 

 

MAINTENANCE TASKS

 

 

 

 

 

only by after-sales service.

 

 

 

 

 

 

The indicator lamp (item.28)

 

Cleaning strainer in water connection

 

motor/electronics module is lit

 

(HDS 745, HDS 695 S, HDS 895 S, HDS 995,

 

(only HDS 995 and HDS 1295)

 

HDS 1195, HDS 1295, HDS Super)

 

* This warning lamp lights up when certain

 

Figure 10

 

 

maintenance work is necessary due to

 

Remove strainer

 

 

accumulated operating hours.

 

Clean in water and re-insert

 

* When you open the cover (item 8) of the

 

 

 

 

Cleaning strainer in low water protection

 

 

compartment (item 6) the electronic display is

 

(HDS 745, HDS 695 S, HDS 895 S, HDS 995,

 

 

visible in the window (item 4).

 

HDS 1195, HDS 1295, HDS Super)

 

* Upon completing the necessary maintenance

 

Figure 11

 

 

work the RESET button next to the display

 

Unfasten union nut and detach hose

 

 

must be depressed at least 7 seconds until

 

Figure 12

 

 

the warning lamp goes out.

 

 

 

 

 

 

Take out strainer

 

Display

 

If necessary, screw in bolt M8 approx. 5mm to

 

 

 

 

 

pull out strainer.

 

 

 

 

 

Clean strainer in water

 

Necessary maintenance work

 

Slide in strainer

 

Visual inspection

 

Mount hose

 

Check that the high-pressure connections do

 

Tighten union nut

 

 

not leak

 

 

 

 

Clean the fuel tank and the filter

 

Cleaning filter at cleaning-agent suction

 

Display

 

hose

 

 

(HDS 745, HDS 695 S, HDS 895 S, HDS 995,

 

 

 

 

 

HDS 1195, HDS 1295, HDS Super)

 

 

 

 

 

 

 

 

Necessary maintenance work

 

 

 

 

Check that the pump does not leak

 

Figure 13

 

Change the pump's oil

 

Pull the cleaning agent suction inlet pipe out

 

Clean strainer in water connection

 

Clean filter in water and re-insert

Clean the strainer (coarse) fitted in front of the

low water protection

Changing oil

 

 

Display

(HDS 745, HDS 695 S, HDS 895 S, HDS 995,

HDS 1195, HDS 1295, HDS Super)

 

 

 

 

Figure 14

Necessary maintenance work

Provide a collecting container for approx. 1

Decarbonise the heating coil *

 

litres of oil

Descale the heating coil *

 

Loosen starting screw

Clean/replace the ignition electrodes *

Clean/replace the burner jet *

* Dispose of used oil in appropriate manner or

Adjust the burner *

hand in at a collection point.

 

 

Page 10
Image 10
Karcher HDS 1195, HDS 1295, HDS 895 S, HDS 695 S, HDS 745 manual Once a month, Display, Clean strainer in low water protection